What does your Mitsubishi Heavy Industries fault code mean?

Pick the code showing on your remote, wall controller or indoor unit and see what it means, what commonly causes it, and what is safe to check yourself. This page covers 54 Mitsubishi Heavy Industries fault codes for units sold in Australia, compiled from official Australian manufacturer and distributor documentation, the same references our own technicians carry.

Heads up: Mitsubishi Heavy Industries uses the same code with different meanings on different product ranges, so check the model range shown next to the code.

Every Mitsubishi Heavy Industries fault code at a glance

Some models show faults as a flashing-light pattern instead of a code; documented lamp patterns are listed alongside their codes.

Code What it means How serious Most likely cause What you can check yourself
E1 (Systems with a wired wall controller (ducted, cassette, multi-head and splits with an optional wired remote)) The wired wall controller has lost communication with the indoor unit. Minor fault Broken or incorrectly connected controller wiring Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E10 (Ducted and KX systems with multiple indoor units on one controller) Too many indoor units are wired to one wall controller (more than 16). Minor fault Too many indoor units connected to the one controller Nothing safe to check yourself. Book a technician.
E11 (Ducted and KX systems with multiple indoor units) The indoor unit addresses have not been set correctly. Minor fault Address setting mistake during installation or service Nothing safe to check yourself. Book a technician.
E12 (KX ducted and multi-head systems) Indoor unit addresses were set using a mix of automatic and manual methods, which the system does not allow. Minor fault Address setting mistake during installation Nothing safe to check yourself. Book a technician.
E14 (Ducted and cassette systems with master and slave wall controllers) The master and slave wall controllers are not set up correctly. Minor fault No controller assigned as the master Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E16 (All systems (split, ducted, multi-head and cassette))also shown as Run light flashes 6 times, Timer light on (hi-wall splits) The indoor fan motor is not spinning at the speed it should, so the unit has stopped. Fault – service needed Faulty indoor fan motor Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E18 (KX ducted and multi-head systems with master and slave indoor units) The master and slave indoor unit addresses are not set correctly. Minor fault Address setting error on the master indoor unit Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E19 (Ducted and cassette indoor units) The indoor unit has been left in its installer check mode. Minor fault Service switch left in the check position after installation or maintenance Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E2 (KX ducted and multi-head systems with several indoor units on one network) The system has found two indoor units set to the same address, so it cannot tell them apart. Minor fault Address setting mistake during installation Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E20 (Ducted and cassette indoor units) The indoor fan motor speed reading is abnormal. Fault – service needed Faulty indoor fan motor Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E21 (Cassette systems (FDT series) with the panel switch, and splits with an air inlet panel) The unit thinks its air inlet panel or filter panel is open or not seated properly. Minor fault Return air grille or filter panel not clicked fully shut after filter cleaning If you have recently cleaned the filters, check the return air grille or panel is latched fully shut
E28 (Systems with a wired wall controller) The temperature sensor built into the wall controller is faulty. Minor fault Broken sensor wire inside the controller Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E3 (Splits and KX systems)also shown as Run light on, Timer light flashes 6 times (hi-wall splits, shared with E5) The indoor unit cannot find the outdoor unit on the signal line. Fault – service needed No power reaching the outdoor unit Check the isolator switch next to the outdoor unit is turned on
E31 (KX systems with multiple outdoor units) Two outdoor units on the same network have been given the same address. Minor fault Address setting mistake on the outdoor units Nothing safe to check yourself. Book a technician.
E32 (KX systems (including ducted and cassette indoor units connected to a KX outdoor unit)) One phase of the three phase power supply is missing, or the phases are connected in the wrong order. Fault – service needed Tripped breaker or blown fuse on one phase at the switchboard Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so
E33 (Ducted and packaged systems) The outdoor unit has measured abnormal electrical current on the inverter power input. Fault – service needed Power supply problem Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so
E34 (Three phase ducted and packaged systems) The outdoor unit has detected a missing phase in its power supply. Fault – service needed Tripped breaker or blown fuse on one phase at the switchboard Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so
E35 (All systems (split, ducted, multi-head and cassette))also shown as Run light on, Timer light keeps flashing (hi-wall splits) The outdoor coil has become too hot while cooling, so the system has stopped to protect itself. Fault – service needed Blocked or dirty outdoor coil, or hot air trapped around the outdoor unit Clear leaves, weeds and stored items away from the outdoor unit so air can flow freely around it
E36 (All systems (split, ducted, multi-head and cassette))also shown as E36-1, E36-2, Run light on, Timer light flashes 5 times (hi-wall splits) The compressor has run too hot, so the system has shut down to protect it. Urgent – turn it off Refrigerant shortage from a leak Clear leaves, weeds and stored items away from the outdoor unit so air can flow freely around it
E36-3 (KX6 ducted and multi-head systems) Liquid refrigerant is flooding back to the compressor instead of gas, so the system has stopped to protect it. Fault – service needed Refrigerant overcharge Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E37 (All systems (split, ducted, multi-head and cassette))also shown as E37-1, E37-2, E37-3, E37-4, E37-5, E37-6, Run light keeps flashing, Timer light flashes 2 times (hi-wall splits) An outdoor coil temperature sensor is giving a faulty reading (on KX systems, E37-5 and E37-6 are the sub cooling coil sensors). Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E38 (All systems (split, ducted, multi-head and cassette))also shown as Run light keeps flashing, Timer light flashes 1 time (hi-wall splits) The outdoor air temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E39 (All systems (split, ducted, multi-head and cassette))also shown as E39-1, E39-2, Run light keeps flashing, Timer light flashes 4 times (hi-wall splits) The compressor discharge pipe temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E40 (All systems (split, ducted, multi-head and cassette))also shown as Run light flashes 7 times, Timer light flashes 1 time (hi-wall splits) Refrigerant pressure has risen too high, or the outdoor unit’s gas service valve is closed, so the system has stopped. Urgent – turn it off Service valve left closed after installation or service Clean the return air filters if they are dusty
E41 (Multi-head, ducted, cassette (PAC) and KX systems)also shown as E41-1, E41-2, Run light on, Timer light flashes 4 times (older multi-head heads), Run light keeps flashing, Timer light flashes 6 times (older multi-head heads) The outdoor unit’s inverter power transistor has overheated or failed, or its temperature sensor is faulty. Fault – service needed Restricted airflow over the outdoor unit’s electronics Clear leaves, weeds and stored items away from the outdoor unit so air can flow freely around it
E42 (All systems (split, ducted, multi-head and cassette))also shown as E42-1, E42-2, Run light on, Timer light flashes 1 time (hi-wall splits) The compressor drew too much electrical current and was shut down (current cut). Fault – service needed Compressor locked or seized Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E43 (KX ducted and multi-head systems)also shown as E43-1, E43-2 More indoor units, or more total indoor capacity, are connected than the outdoor unit supports. Minor fault Address setting mistake on indoor or outdoor units Nothing safe to check yourself. Book a technician.
E44 (Ducted, packaged and KX systems)also shown as E44-1, E44-2 Liquid refrigerant is flooding back to the compressor instead of gas. Fault – service needed Refrigerant overcharge Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E45 (Multi-head, ducted and cassette (PAC) outdoor units and KX systems)also shown as E45-1, E45-2 The inverter board and the main control board in the outdoor unit have stopped talking to each other. Fault – service needed Loose or broken wiring between the outdoor boards Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E46 (KX ducted and multi-head systems) Indoor unit addresses on the same network were set with a mix of automatic and manual methods. Minor fault Address setting mistake during installation Nothing safe to check yourself. Book a technician.
E47 (Splits, multi-head, ducted and packaged systems)also shown as Run light flashes 5 times, Timer light on (hi-wall splits) The outdoor unit’s active filter has detected abnormal power supply voltage. Fault – service needed Wrong voltage connected to the power supply Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E48 (All systems (split, ducted, multi-head and cassette))also shown as E48-1, E48-2, Run light on, Timer light flashes 7 times (hi-wall splits) The outdoor fan motor is not spinning properly, so the unit has stopped. Fault – service needed Faulty outdoor fan motor Look through the outdoor unit grille and check nothing like a stick or vine is visibly jamming the fan. Do not put anything through the grille
E49 (Ducted, packaged and KX systems) Refrigerant pressure has dropped too low, so the system has stopped. Fault – service needed Refrigerant shortage from a leak Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E5 (All systems (split, ducted, multi-head and cassette))also shown as Run light on, Timer light flashes 6 times (hi-wall splits) The indoor and outdoor units have stopped talking to each other. Fault – service needed Damaged or loose interconnecting cable between the units Check the isolator switch next to the outdoor unit is turned on
E51 (All systems (split, ducted, multi-head and cassette))also shown as E51-1, E51-2, Run light on, Timer light flashes 4 times (hi-wall splits) The inverter power transistor in the outdoor unit has failed or overheated. Fault – service needed Faulty power transistor Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E53 (Multi-head, ducted, packaged and KX systems)also shown as E53-1, E53-2 The compressor suction pipe temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E54 (Ducted, packaged, multi-head and KX systems)also shown as E54-1, E54-2 A refrigerant pressure sensor (high or low pressure) is giving a faulty reading. Fault – service needed Faulty pressure sensor Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E55 (Ducted, packaged and KX systems)also shown as E55-1, E55-2 The compressor under dome temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E56 (KX ducted and multi-head systems)also shown as E56-1, E56-2 The power transistor temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E57 (All systems (split, ducted, multi-head and cassette))also shown as Run light flashes 7 times, Timer light on (hi-wall splits) The system has detected it is short of refrigerant, or a service valve is closed. Fault – service needed Refrigerant leak Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E58 (All systems (split, ducted, multi-head and cassette))also shown as E58-1, E58-2, Run light on, Timer light flashes 3 times (hi-wall splits) The compressor cannot keep up with the speed asked of it, so it has been slowed or stopped to protect itself. Fault – service needed System working overloaded in very hot conditions or with blocked coils Clean the return air filters if they are dusty
E59 (Ducted, cassette (PAC) and KX systems)also shown as E59-1, E59-2 The compressor failed to start. Fault – service needed Faulty compressor motor or bearing Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E59 (Hi-wall splits and SCM multi-head systems)also shown as Run light on, Timer light flashes 2 times (hi-wall splits and multi-head heads) The outdoor unit has shut itself down because of an internal fault, or because it is drawing less power than it should. Fault – service needed Broken or disconnected compressor wiring Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E6 (Ducted, cassette and multi-head indoor units)also shown as Run light flashes 7 times, Timer light on (older multi-head heads, closed service valve) The indoor coil temperature sensor is giving a faulty reading. On older multi-head systems E6 can also mean the unit detected no cooling at the indoor coil, usually because a service valve was left closed. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E60 (All systems (split, ducted, multi-head and cassette))also shown as E60-1, E60-2, Run light flashes 2 times, Timer light flashes 2 times (hi-wall splits) The outdoor unit cannot detect the position of the compressor motor, so the compressor will not run (rotor lock). Fault – service needed Faulty compressor Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E61 (KX systems with multiple outdoor units working together)also shown as E61-1, E61-2 The master outdoor unit has lost communication with a slave outdoor unit. Fault – service needed Signal wiring fault between the outdoor units Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E63 (KX ducted and multi-head systems with an emergency stop input) The system has been stopped by an external emergency stop signal. Urgent – turn it off Emergency stop input activated by connected external equipment Check whether another system in the building (such as a fire or safety panel) has triggered the stop, then contact your technician
E7 (Ducted, cassette and multi-head indoor units) The return air temperature sensor is giving a faulty reading. Fault – service needed Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
E8 (Ducted and cassette systems) The indoor coil has become too hot while heating, so the unit has stopped to protect itself. Fault – service needed Dirty return air filters restricting airflow Clean the return air filters if they are dusty
E9 (Ducted, cassette and multi-head indoor units fitted with a drain pump) The drain safety switch has detected condensate water that is not draining away properly. Fault – service needed Blocked condensate drain line Look at where the drain pipe ends outside and clear any visible dirt, mulch or debris away from the outlet
Run 1 flash + Timer on (Hi-wall splits and multi-head wall-mounted heads)also shown as Run light flashes 1 time, Timer light on (no code on display) The indoor coil temperature sensor is giving a faulty reading. Minor fault Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
Run 2 flashes + Timer on (Hi-wall splits and multi-head wall-mounted heads)also shown as Run light flashes 2 times, Timer light on (no code on display) The room temperature sensor is giving a faulty reading. Minor fault Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
Run 3 flashes + Timer on (Hi-wall splits and multi-head wall-mounted heads)also shown as Run light flashes 3 times, Timer light on (no code on display) The second indoor coil temperature sensor is giving a faulty reading. Minor fault Broken sensor wire or loose connector Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
Run 4 flashes + Timer on (Hi-wall splits with the wifi (wireless LAN) module)also shown as Run light flashes 4 times, Timer light on (no code on display) The unit has lost contact with its wifi module, so app control may not work; heating and cooling can usually continue. Minor fault Faulty wifi interface board Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

Codes that mean switch the system off

If your Mitsubishi Heavy Industries unit shows E36, E40, E63, turn the system off at the isolator and leave it off. These faults involve the compressor, refrigerant or electrical protection, and running the unit can cause further damage.

The most serious Mitsubishi Heavy Industries fault codes explained

What does Mitsubishi Heavy Industries fault code E36 mean? (All systems (split, ducted, multi-head and cassette))

The compressor has run too hot, so the system has shut down to protect it.

Likely causes:

  • Refrigerant shortage from a leak
  • Service valve not fully open
  • Faulty discharge pipe sensor
  • Restricted airflow

Safe checks before you call:

  • Clear leaves, weeds and stored items away from the outdoor unit so air can flow freely around it
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
  • If the fault comes back after a restart, stop using the system until it is checked

What does Mitsubishi Heavy Industries fault code E40 mean? (All systems (split, ducted, multi-head and cassette))

Refrigerant pressure has risen too high, or the outdoor unit’s gas service valve is closed, so the system has stopped.

Likely causes:

  • Service valve left closed after installation or service
  • Blocked airflow through the indoor or outdoor unit
  • Dirty return air filters while heating
  • Faulty high pressure sensor or switch
  • Faulty outdoor circuit board

Safe checks before you call:

  • Clean the return air filters if they are dusty
  • Clear leaves, weeds and stored items away from the outdoor unit so air can flow freely around it
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again
  • If the fault comes back after a restart, stop using the system until it is checked

What does Mitsubishi Heavy Industries fault code E63 mean? (KX ducted and multi-head systems with an emergency stop input)

The system has been stopped by an external emergency stop signal.

Likely causes:

  • Emergency stop input activated by connected external equipment
  • Building safety interlock triggered
  • Wiring fault on the external input terminal

Safe checks before you call:

  • Check whether another system in the building (such as a fire or safety panel) has triggered the stop, then contact your technician

What does Mitsubishi Heavy Industries fault code E3 mean? (Splits and KX systems)

The indoor unit cannot find the outdoor unit on the signal line.

Likely causes:

  • No power reaching the outdoor unit
  • Mismatched pairing between indoor and outdoor units
  • Missing, broken or loose signal wiring
  • Faulty indoor or outdoor circuit board

Safe checks before you call:

  • Check the isolator switch next to the outdoor unit is turned on
  • Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E5 mean? (All systems (split, ducted, multi-head and cassette))

The indoor and outdoor units have stopped talking to each other.

Likely causes:

  • Damaged or loose interconnecting cable between the units
  • Power lost to the outdoor unit
  • Faulty indoor or outdoor circuit board
  • Address setting error on multi-unit systems
  • Wall controller wiring fault or unit address error (KX systems, where E5 means communication was lost during operation)

Safe checks before you call:

  • Check the isolator switch next to the outdoor unit is turned on
  • Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E6 mean? (Ducted, cassette and multi-head indoor units)

The indoor coil temperature sensor is giving a faulty reading. On older multi-head systems E6 can also mean the unit detected no cooling at the indoor coil, usually because a service valve was left closed.

Likely causes:

  • Broken sensor wire or loose connector
  • Faulty sensor element
  • Faulty indoor circuit board
  • Service valve on the outdoor unit left closed (older multi-head systems)

Safe checks before you call:

  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E7 mean? (Ducted, cassette and multi-head indoor units)

The return air temperature sensor is giving a faulty reading.

Likely causes:

  • Broken sensor wire or loose connector
  • Faulty sensor element
  • Faulty indoor circuit board

Safe checks before you call:

  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E8 mean? (Ducted and cassette systems)

The indoor coil has become too hot while heating, so the unit has stopped to protect itself.

Likely causes:

  • Dirty return air filters restricting airflow
  • Closed or blocked supply and return vents
  • Faulty indoor coil sensor
  • Faulty indoor circuit board

Safe checks before you call:

  • Clean the return air filters if they are dusty
  • Make sure supply and return air vents are open and not covered by furniture or rugs
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E9 mean? (Ducted, cassette and multi-head indoor units fitted with a drain pump)

The drain safety switch has detected condensate water that is not draining away properly.

Likely causes:

  • Blocked condensate drain line
  • Faulty drain pump or broken drain pump wiring
  • Float switch stuck or faulty
  • Drain pipe installed at the wrong fall

Safe checks before you call:

  • Look at where the drain pipe ends outside and clear any visible dirt, mulch or debris away from the outlet
  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E16 mean? (All systems (split, ducted, multi-head and cassette))

The indoor fan motor is not spinning at the speed it should, so the unit has stopped.

Likely causes:

  • Faulty indoor fan motor
  • Loose or poor motor connector connection
  • Something jamming the fan
  • Faulty indoor circuit board or blown fuse

Safe checks before you call:

  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E20 mean? (Ducted and cassette indoor units)

The indoor fan motor speed reading is abnormal.

Likely causes:

  • Faulty indoor fan motor
  • Something caught in the fan
  • Faulty indoor power circuit board
  • Electrical noise or a blown fuse

Safe checks before you call:

  • Turn the system off at the isolator or circuit breaker, wait five minutes, then turn it back on and try again

What does Mitsubishi Heavy Industries fault code E32 mean? (KX systems (including ducted and cassette indoor units connected to a KX outdoor unit))

One phase of the three phase power supply is missing, or the phases are connected in the wrong order.

Likely causes:

  • Tripped breaker or blown fuse on one phase at the switchboard
  • Fault in the incoming power supply
  • Faulty outdoor circuit board

Safe checks before you call:

  • Check your switchboard for a tripped circuit breaker and reset it if it is safe to do so

Fault confirmed? Here is what to do next

A fault code is the starting point, not the fix. Start here:

Call us on 08 8296 7888 or book online and we will call or text you back ASAP.

Sources for this page

Every Mitsubishi Heavy Industries code above is checked against these Australian documents. Open them yourself to verify anything on this page:

Mitsubishi Heavy Industries fault code FAQs

Where do I find the fault code on a Mitsubishi Heavy Industries air conditioner?

Check the remote or wall controller display first. Some models flash the indoor unit’s lamps in a pattern instead; the table above lists documented lamp patterns alongside their codes. If nothing is showing, the code may only appear while the fault is active.

Can I clear a Mitsubishi Heavy Industries fault code myself?

You can reset the system by turning it off at the isolator or breaker for five minutes. If the code stays gone, it was a one-off. If it returns, the fault is real and needs a licensed technician, and repeated resets can cause further damage on compressor or refrigerant faults.

Does a Mitsubishi Heavy Industries fault code mean I need a new air conditioner?

Usually not. Most codes point to repairable faults like sensors, fan motors or drainage. Our fault find gives you an honest verdict either way, and the fee is credited if you repair with us.

Are these Mitsubishi Heavy Industries fault codes correct for Australian models?

Yes. Every code on this page was checked against Australian documentation (mhiaa.com.au, extrordinair.com.au, compareairconditioning.com.au), not overseas lists, because the same code can mean different things in different markets. Meanings still vary between model series, so treat this page as reference and cross-check your unit’s manual.

Fault codes for other brands

Not a Mitsubishi Heavy Industries? Every brand below follows the same format: the documented Australian codes, what each one means, how serious it is and what is safe to check yourself.

Mitsubishi Electric codes have their own library: Mitsubishi Electric fault codes. Or start from the full fault code lookup, which covers more than 1,000 codes across 15 brands sold in Australia.

Written by Oliver Hastings, T&K Airpower. Last updated 14/09/2026. Compiled from Australian sources including mhiaa.com.au, extrordinair.com.au, compareairconditioning.com.au, so you can check every code against the official documentation. Fault code meanings vary between model series and controllers, so treat this page as reference only and never remove panels or work on the refrigeration or electrical parts of the system yourself.

T&K Airpower - Air Conditioner and Electrician Repair experts in Adelaide

Established, Local, and Accountable

We’ve been working in Adelaide homes for over 30 years.

Every job is done by our own technicians, employed, not subcontracted, so the person on your roof or at your switchboard is accountable for the work. We back it with a lifetime workmanship warranty, and we’ll be here to stand behind it long after the job is done.

ExcellentGoogle star 1Google star 2Google star 3Google star 4Google star 54.9671 reviews
4.9Google star 1Google star 2Google star 3Google star 4Google star 5
Excellent671 reviews
Posted on Google Google
Kaye Cleave profile picture
Kaye Cleave
81 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Great service and professional staff. Thank you T& K Airpower. I'm very happy with my new air-conditioner and would highly recommended your company

Owner's reply
Thank you, Kaye! We're thrilled you're happy with your new air-conditioner and appreciate your kind recommendation. It was a pleasure assisting you! Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Boti Nagy profile picture
Boti Nagy
140 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Been having my home air conditioning serviced by T&K for years and always impressed with how this company operates. From booking an appointment with a repairman to job completion, this is a truly professional operation. But it hasn't lost the human touch. To my surprise and delight, my repairman Daniel rang to inform me he might be later than anticipated because the job he was completing was taking longer. He wasn't that late in the end and was friendly, genial and, most importantly, efficient and professional. Stayed true to the quoted price too, which didn't break the bank. Highly recommend T&K.

Owner's reply
Thank you so much for your review! Means the world to us hearing great feedback about our team! I will pass this on to Dan and the office Team 😊
Posted on Google Google
Jan Sutherland profile picture
Jan Sutherland
515 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Quick, efficient and well priced. Technician was very polite, knowledgeable and completed the task with minimal fuss or disruption. Will definitely use this company in the future.

Owner's reply
Thank you, Jan! We're delighted to hear about your positive experience with our technician. We look forward to assisting you again whenever you need us. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Kosta Sotiropoulos profile picture
Kosta Sotiropoulos
561 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+2
As Director of CS Real Estate managing a Property Portfolio, one of our business objectives is that we only partner with quality suppliers / tradespeople. Working with high performing and reputable businesses is nonnegotiable. In late 2024 I contacted T&K Airpower for two separate maintenance jobs. From the moment I made contact with them, I found them to be extremely responsive, reliable and most importantly experts in what they do. There quotes and pricing is very competitive. And further to that, with each job I received a detailed invoice and photos of the works undertaken. I've attached some pictures of the new PC Board installed along with the new wall controller. I wouldn't hesitate recommending T&K Airpower, Cindy, Julie and the entire team do a great job. As a customer, I know my landlords are in great hands. Thank you to the team at T&K Airpower.

Owner's reply
Thank you, Kosta, for your thoughtful review and kind words about our team! We're thrilled to hear about your positive experience and look forward to continuing to support your property portfolio needs. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Aaron Albino profile picture
Aaron Albino
567 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+1
The guys were half an hour earlier than expected. Although it was nearly two weeks from when I put the warranty claim in with Hitachi.They were very thorough in their inspection and completely contradictory to the installers opinion who said it was a fault with the unit itself. The problem is still unresolved !

Owner's reply
We're sorry to hear this, Aaron. Please contact our customer service so we can assist you further and help resolve the issue promptly. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Davin & Jodie Pickard profile picture
Davin & Jodie Pickard
631 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+1
Excellent communication and on site service

Owner's reply
Thank you, Davin and Jodie, for your kind words! We're thrilled to hear you enjoyed our communication and on-site service. Your feedback motivates us to keep delivering quality service. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
T & J Air Conditioning profile picture
T & J Air Conditioning
792 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
T & K were very professional. They handled our warranty claim with Mitsubishi Electric within a few days. The technician Nathan was great to deal with and communicated well.

Owner's reply
Thank you, Tom! We're glad to hear Nathan and the team at T & K provided you with excellent service. Your satisfaction with our warranty process means a lot to us.

(Translated by Google, see original)
Posted on Google Google
Charles Bartlett profile picture
Charles Bartlett
0 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Most excellent thorough friendly service. Makes a nice change from what you get elsewhere.
Posted on Google Google
Larry Rawlins profile picture
Larry Rawlins
1 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service, Ciaran was a very friendly and knowledgeable technician.
Posted on Google Google
Gilbertt Kat profile picture
Gilbertt Kat
4 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Cieran did our air conditioner service today. Very efficient, lovely guy, no fuss, explained thoroughly about the status of my unit. Thoroughly recommend!!

Owner's reply
Hi Gilbertt! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Ciaran got your air conditioning servicing sorted in Tusmore. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lucia Puzella profile picture
Lucia Puzella
5 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We had our solar panel's serviced on the 9/9/26 by Tristan, I was extremely impressed and happy with his professionalism. We also have our air-conditioning service with them. I would highly recommend them, that's why they deserved a 5 star. Thankyou T&K Air-conditioning and Electrical.

Owner's reply
Hi Lucia! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lyn and Wolfgang Zeidler profile picture
Lyn and Wolfgang Zeidler
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Efficient timely service

Owner's reply
Hi Lyn! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mario Pepicelli profile picture
Mario Pepicelli
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby was excellent, a really skilled tradesman. Worked out the issue with the air conditioner explained the options available. Once I selected the option he carried out the repair works.

Owner's reply
Hi Mario! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Barbara Isaacson profile picture
Barbara Isaacson
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Extremely happy, very thorough and friendly been using T&K Airpower for some 20 years plus, and have never had to complain about their service. Had a Solar Health Check done, and an Electrical Switch Board Upgrade that was badly needed, service was second to none, highly recommend. Price all up was good, and peace of mind guaranteed. 😀😀

Owner's reply
Thanks so much for your kind words! Have a lovely weekend! 👍😁
Posted on Google Google
Jamin Stojsavljevic profile picture
Jamin Stojsavljevic
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great experience. 1st place I’ll call now for repairs or a new system. Excellent technical knowledge, friendly, answered all of my questions. Fix and upgrade of my existing system was well done and installers were considerate, friendly and knowledgeable.

Owner's reply
Hi Jamin! Really appreciate the kind words, reviews like this mean a lot to us. Glad Jacob could look after your air conditioning repairs in WALKERVILLE. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Paul Maschgan profile picture
Paul Maschgan
10 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
If you're looking for a company that provides excellent communication, tradespeople who arrive on time, outstanding workmanship (thanks Tristan & Jacob) and leave everything clean and tidy then T & K Airpower is the company you are looking for. From my first contact with the office staff through to the completion of the work, the entire process was professional and hassle free. Nothing was too much trouble, and the team was friendly, knowledgeable, and happy to answer any questions. After reading the reviews before choosing T & K Airpower, I had high expectations, and I am pleased to say they were spot on. I would not hesitate in recommending them to anyone looking for quality air conditioning service and installation.

Owner's reply
Thank you so much, Paul, for your thoughtful feedback! We're thrilled to hear that Tristan, Jacob, and the team delivered a seamless experience. Your recommendation means a lot to us. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Ben Nicholls profile picture
Ben Nicholls
11 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Always great service and advice from the T&K AirPower crew. Been using them forever, never any issues

Owner's reply
Hi Ben! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Ciaran got your electrical servicing sorted in Hampstead Gardens. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Bernard McCallum profile picture
Bernard McCallum
11 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Last week we had a replacement air conditioning system installed by T&K. Technicians Oliver/Kieran and Noah attended all day Wednesday 21/2/24. Oliver attended Friday 23/2/24. The work performed was outstanding. My wife and I rate very highly the service provided before the installation and during the installation. Should you consider utilising T&K you won’t regret it. What we rate very highly was the professionalism and meticulous care taken.

Owner's reply
Hi Bernard! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Malcolm Skilton profile picture
Malcolm Skilton
12 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I frequently base my assessment of any service provider on first contact. In the case of T&K Airpower Air Conditioning and Electrical, first contact was very positive. The quote I received was very reasonable (especially with the seniors discount), and I accepted that quote without needing to go to any other providers. The service tech (Nathan) arrived when scheduled and was very polite and helpful. He completed the required work efficiently, and within a very reasonable time frame. I would no hesitation in useing this company again.

Owner's reply
Hi Malcolm! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Nathan got your air conditioning servicing sorted in Craigmore. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Meg Michell profile picture
Meg Michell
14 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Fabulous service

Owner's reply
Hi Meg! Thanks so much for the great review, it genuinely means a lot to the team. So glad Ciaran could help you out with your air conditioning servicing in North Adelaide. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Michael Cusack profile picture
Michael Cusack
14 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
The guys were great. Very professional and personable. They worked hard and cleaned up before they left. Highly recommended and I would highly recommend them. So good these days to get prompt and professional help.

Owner's reply
Hi Michael! Really appreciate the kind words, reviews like this mean a lot to us. Glad Oliver could look after your air conditioning installation in Birdwood. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Rosslyn Eftimiou profile picture
Rosslyn Eftimiou
15 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Ciaran was friendly and very professional. Excellent service

Owner's reply
Hi Rosslyn! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Jodie Bradbrook profile picture
Jodie Bradbrook
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
This business has exceptional customer service and lovely technicians. They do quality work and are great to deal with. Highly recommend.

Owner's reply
Hi Jodie! Thanks so much for the great review, it genuinely means a lot to the team. So glad Tristan could help you out with your air conditioning repairs over in Richmond. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
ZoZo's YouTube Channel profile picture
ZoZo's YouTube Channel
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Prompt and professional service

Owner's reply
Hi ZoZo's! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Peter Dalton profile picture
Peter Dalton
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We were being gassed by an old Daiken air conditioner losing its refrigerant and causing headaches in our Study. We called T&K AirPower through our RAA membership, their technician / salesman Toby arrived promptly and was able to spot the problem then present options which became a reasonably priced new Mitsubishi unit which we coupled with another unit for our adjacent Guest Bedroom working off the same fan coil unit. He spent time on a solution for an on roof mounted unit for our Family Room. The installation team Oliver, Luke and Giaran did a great install including a new electrical circuit. Definitely a 5 Star review but for a couple of old dodgy baby boomers, I was impressed with the ease of communication and professionalism.

Owner's reply
Hi Peter! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Sam Catley profile picture
Sam Catley
24 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
A great big thankyou to Toby, Oliver, Nick, Noah & the T&K Air Team for your brilliant service. You were professional, knowledgeable & surpassed our expectations. We are thrilled with our new ducted aircon.

Owner's reply
Hi Sam! Thank you for the lovely review, the team was stoked to see it. So good to hear Noah took care of your air conditioning installation for you in Prospect. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Winston Head profile picture
Winston Head
25 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby is a very knowledgeable, he explained many things about our AC that we had no idea about. He suggested several things that would make our unit run better and more efficiently, saving $$$ and work. We have no hesitation in recommending Toby for any AC service.

Owner's reply
Hi Winston! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Tobias got your air conditioning servicing sorted in Highbury. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lyn Jefferies profile picture
Lyn Jefferies
28 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service & prompt attention. Good price for a country job too.

Owner's reply
Thank you, Lyn! We're thrilled you were pleased with our service and pricing. Your feedback means a lot to us!
Posted on Google Google
Bob Aston profile picture
Bob Aston
28 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service. Kieran was right on time, went about the job in an efficient and organised way and completed it within the given timeframe. Cost as expected. We would recommend the company any time.

Owner's reply
Thank you, Bob! We're thrilled to hear about your positive experience with Kieran. Your recommendation means a lot to us and we look forward to assisting you again in the future. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Sally Huefner profile picture
Sally Huefner
30 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Last thing you need mid winter is the heating to stop working so a call to T&K and Toby was out to diagnose and fix the system. Great service, quickly found the problem, had the part on the van and soon it was warm again inside. Highly recommended Toby and the team at T&K AirPower.

Owner's reply
Hi Sally! Thanks so much for the great review, it genuinely means a lot to the team. So glad Tobias could help you out with your air conditioning repairs over in Hazelwood Park. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Daniel Dieckmann profile picture
Daniel Dieckmann
30 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Happy with Jacob on a/c service and replacement 2 fan motors. All working well.

Owner's reply
Hi Daniel! Thanks so much for the great review, it genuinely means a lot to the team. So glad Jacob could help you out with your air conditioning repairs in Glengowrie. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mike Munday profile picture
Mike Munday
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We contacted T&K Airpower to arrange some repairs on our Temperzone air conditioner. I called them on a Thursday and they had a technician (Toby) available on the following Monday morning 3 August. Our controller was not working properly and stopped working altogether the day before Toby came. When he arrived he checked what we wanted done and which we discussed with him. He said he wanted to have a look at the unit outside to see if he could at least get the air conditioner working. As he was doing this a solenoid fused with a large bang so he couldn’t do anything else until that part was replaced. He contacted the office to arrange a quote so they could commence sourcing the parts. The controller took longer than expected to source and the job was booked in for Friday 14 August but due to another job being postponed we had our job brought forward to Wednesday 12 August which was most appreciated due to having a very cold house during this period. The technician that completed our work was Artie and he was absolutely fantastic. When he arrived we went through everything that had to be done which we were advised would take up to about 5 hours. The new controller had to be completely re wired, the new solenoid fitted and the whole system serviced. We also replaced 3 hard wired fire alarms replaced. Artie was very tidy and respectful and polite in every way. We would request his services if that was possible should we have any further issues that need attention. Also the young ladies in the office being Alicia and Ebony were also very helpful and courteous every time I dealt with them on the phone. The total cost was just over $2300 which we thought was reasonable for the efficiency and the job being completed by a quality technician in Artie.

Owner's reply
Hi Mike! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Travers Gebler profile picture
Travers Gebler
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
On-time, very easy to deal with. Enthusiastic & polite crew. Recommend for sure.

Owner's reply
Hi Travers! Thank you for the lovely review, the team was stoked to see it. So good to hear Noah took care of your air conditioning installation for you in Kidman Park. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Chris Boyd profile picture
Chris Boyd
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Excellent communication, professional conduct, and reasonable price

Owner's reply
Hi Chris! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tristan could look after your air conditioning servicing in Virginia. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Petre Thorn profile picture
Petre Thorn
32 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby was on time, professional and knowledgeable.

Owner's reply
Hi Petre! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Phil Bancroft profile picture
Phil Bancroft
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Arrived on time. Very friendly. Explained everything. Always very happy.

Owner's reply
Hi Phil! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Kate G profile picture
Kate G
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Nathan was efficient, friendly and provided useful information. Thanks

Owner's reply
Hi Kate! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
babis babas profile picture
babis babas
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We could not be happier. Great service and our system has never worked so well before! Thanks guys.

Owner's reply
Hi babis! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
yueqiang zhang profile picture
yueqiang zhang
36 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Good service. Thanks Toby and T&K. Will be looking for some discounts for next service

Owner's reply
Hi yueqiang! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Angie Evans profile picture
Angie Evans
40 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Nathan arrived promptly, was friendly, completed the task required and provided information for future work. Pleased we chose T&K

Owner's reply
Hi Angie! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mark Seatree profile picture
Mark Seatree
40 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Marty is a legend!

Owner's reply
Hi Mark! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Martin got your air conditioning repairs sorted in Rostrevor. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Maris Javier profile picture
Maris Javier
41 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby is an excellent worker. He was respectful and was very efficient. I would say one of the best I've dealt with. Thank you Toby for your competence and professionalism!

Owner's reply
Hi Maris! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Volker Trede profile picture
Volker Trede
42 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Quick turn around, excellent communication. Will use again.

Owner's reply
Hi Volker! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Ken AY profile picture
Ken AY
42 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Used them to investigate an issue with a ducted AC system, attended by professional and experienced technicians who were able to quickly identify and fix the problem.

Owner's reply
Hi Ken! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
jo Stone profile picture
jo Stone
45 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Amazing service. Excellent and trustworthy staff. Highly recommend. Service was easy and delivered with quality. Thank you

Owner's reply
Hi jo! Thank you for the lovely review, the team was stoked to see it. So good to hear Tobias took care of your air conditioning installation for you in Panorama. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Bianca Davidson profile picture
Bianca Davidson
45 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Lovely experience with technician Tristan. He walked me through every step, explained what would benefit my split system and gave me a run down of all my options.

Owner's reply
Hi Bianca! Thank you for the lovely review, the team was stoked to see it. So good to hear Tristan took care of your air conditioning servicing for you in Ingle Farm. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Adrian Hocking profile picture
Adrian Hocking
46 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Absolutely Excellent Service and VERY HAPPY With the price. Service man was very nice and very polite. Thank you so much...

Owner's reply
Hi Adrian! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tristan could look after your air conditioning repairs in Craigmore. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Michael Bowes profile picture
Michael Bowes
47 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Excellent and honest service from Marty

Owner's reply
Hi Michael! Really appreciate the kind words, reviews like this mean a lot to us. Glad Martin could look after your air conditioning repairs in Belair. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Kerry Leaver profile picture
Kerry Leaver
48 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Received fantastic service, advice and support from Toby today. He communicated really well, spent time explaining what the issues were and what my options were. Then the replacement parts I needed were couriered over while Toby waited and my heating was working before he left. So efficient! He also spotted that my smoke alarm was expired which I had not asked him to check.

Owner's reply
Hi Kerry! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tobias could look after your air conditioning repairs in Somerton Park. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Tom profile picture
Tom
49 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We initially had a temporary repair of our old air conditioner. That worked well but a new one was clearly the way to go. The service was uniformly prompt and outstanding. Tobi deserves particular credit for his professional, thorough and non-pushy contribution. Highly recommended. Tom Stubbs

Owner's reply
Hi Tom! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Verified by Trustindex
Trustindex verified badge is the Universal Symbol of Trust. Only the greatest companies can get the verified badge who has a review score above 4.5, based on customer reviews over the past 12 months. Read more
null

With Over 30 Years of Experience, You Can Trust Our Certified Technicians To Do The Job Right The FIRST TIME for your air conditioner and electrician needs.

null

Honest Advice on Your Home's Comfort, Energy and Safety

Every price and answer on this page comes from the same pricing and diagnostics our own technicians use, so what you see is a genuine indication, not a teaser.

Where an upgrade is genuinely needed, we’ll explain why in plain terms and set out your best option. No pressure, no unnecessary work.

We only recommend it when it improves safety, reliability or long-term performance.

We’ll call or text you back ASAP!

Bright green logo with sunburst design

Service Area

null

Servicing Adelaide Homes and Surrounding Suburbs

We provide residential electrical energy solutions and upgrades across metropolitan Adelaide, including inner eastern, western and southern suburbs