What does your ActronAir fault code mean?

Pick the code showing on your remote, wall controller or indoor unit and see what it means, what commonly causes it, and what is safe to check yourself. This page covers 207 ActronAir fault codes for units sold in Australia, compiled from official Australian manufacturer and distributor documentation, the same references our own technicians carry.

Heads up: ActronAir uses the same code with different meanings on different product ranges, so check the model range shown next to the code.

Every ActronAir fault code at a glance

Some models show faults as a flashing-light pattern instead of a code; documented lamp patterns are listed alongside their codes.

Code What it means How serious Most likely cause What you can check yourself
CP (Aurora (SWB) and Serene (WRC/WRE) wall splits and multi-split indoor units (MRE/BRE) (shown as off by remote switch on multi-splits)) The remote on/off terminal is open, which usually means an external switch or energy management device has turned the unit off. Normal operation External demand response or remote switch active Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E0 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (1 lamp flash))also shown as 1 lamp flash The indoor unit’s memory chip (EEPROM) has a parameter error. Fault – service needed Corrupted indoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E0 (Multi-split outdoor units (MRC)) The outdoor unit’s memory chip (EEPROM) has a parameter error. Fault – service needed Corrupted outdoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E0 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) A power phase sequence error or phase failure has been detected (three phase units). Fault – service needed A phase lost at the switchboard Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E01 (Classic 2 (CRA/CCA/EVA/EAA/EFA), Advance (CRV/EVV/EAA/EFV) and Aires (CRS/EVA) ducted systems (NEO, LR7-1 and LC7-2 wall controllers)) The indoor fan is not running at the speed the system asked for (fan RPM feedback error). Fault – service needed Blocked return air filter overloading the fan Clean or check the return air filter is not clogged
E09 (Classic 2, ESP Platinum (shown as E9), Advance, Aires and QUE ducted systems)also shown as E9 The low pressure safety switch has tripped, usually because the system is low on refrigerant. Fault – service needed Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
E1 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display), multi-split indoor units (MRE/BRE) (2 lamp flashes) and the WC-02 wired controller)also shown as 2 lamp flashes The indoor and outdoor units have lost communication with each other. Fault – service needed Damaged or loose interconnecting cable Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
E10 (ESP Platinum, Advance, Aires and QUE ducted systems) The low pressure sensor has failed (open or short circuit). Minor fault Faulty low pressure sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E100 (Advance ducted systems) The drive’s PFC circuit has tripped a hardware overcurrent protection. Fault – service needed Drive power electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E100 (Aires ducted systems) The compressor drive’s charging circuit has a malfunction. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E101 (Advance and Aires ducted systems) The drive’s PFC circuit has tripped a software overcurrent protection. Fault – service needed Drive power electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E102 (Advance and Aires ducted systems) The drive’s PFC circuit has detected excessive voltage. Fault – service needed Mains voltage surge Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E103 (Advance ducted systems with the R-32 (Uno Pro board) outdoor unit and Aires ducted systems)also shown as E103** The drive’s power module temperature reading is abnormally low or its sensor is open circuit. Minor fault Faulty temperature sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E104 (Advance ducted systems with the R-32 (Uno Pro board) outdoor unit and Aires ducted systems)also shown as E104** The drive has locked itself out after reaching its fault limit and needs to be reset and checked. Fault – service needed Repeated drive protection trips Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E11 (Classic 2, ESP Platinum, Advance, Aires and QUE ducted systems) The high pressure safety switch has tripped, usually because the outdoor unit cannot get rid of heat. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E12 (ESP Platinum, Advance, Aires and QUE ducted systems) The high pressure sensor has failed (open or short circuit). Minor fault Faulty high pressure sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E13 (Advance ducted systems with the R-410A (Uno board) outdoor unit; QUE three phase systems can show the same meaning under E13)also shown as E13* The outdoor drive’s HSP connector jumper pin is missing or disconnected. Fault – service needed Jumper pin dislodged or not fitted on the VSD HSP connector Turn the system off at the isolator for 5 minutes, then restart it once. This fault usually needs a technician to reseat the connector.
E13 (Advance, Aires and QUE three phase ducted systems) The outdoor unit’s compressor drive has reported an internal error. Fault – service needed Compressor drive (VSD) fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E14 (ESP Platinum and QUE single phase ducted systems) The condenser pressure is too low for normal operation. Fault – service needed Low refrigerant charge (possible leak) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E15 (ESP Platinum, Advance, Aires and QUE ducted systems) The outdoor unit has lost communication with its compressor speed drive (VSD). Fault – service needed Loose or damaged wiring between the outdoor board and drive Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
E17 (ESP Platinum and QUE single phase ducted systems) A fault has been detected in one of the outdoor unit’s peripheral devices. Fault – service needed Faulty outdoor accessory or sensor circuit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E18 (ESP Platinum, Advance, Aires and QUE ducted systems (E18 open circuit, E19 short circuit on ESP Platinum and QUE single phase))also shown as E19 The suction temperature sensor has failed or is giving an abnormal reading. Minor fault Faulty suction temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E2 (Multi-split outdoor units (MRC)) The indoor and outdoor units have lost communication with each other. Fault – service needed Damaged or loose interconnecting cable Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
E2 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The room temperature sensor (T1) has failed. Minor fault Faulty room temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E2 (ESP Digital and ESP Plus ducted systems (SRD/SRV) with LM7 or LM24 wall controller) The indoor coil outlet temperature sensor has failed (open or short circuit). Minor fault Faulty or disconnected indoor coil-out sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E22 (ESP Platinum, Advance, Aires and QUE ducted systems) The outdoor ambient temperature sensor has failed, and the unit may run in a reduced safe mode. Minor fault Faulty ambient temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E23 (ESP Platinum and QUE single phase ducted systems) The outdoor unit has lost communication with its electronic expansion valve (EEV) board, and the unit runs in safe mode. Fault – service needed Loose or damaged wiring to the EEV board Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E25 (ESP Platinum and QUE single phase ducted systems) The outdoor temperature reading has not updated, which is a status message rather than a breakdown. Normal operation Temporary sensor communication dropout Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E26 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive has detected excessive electrical current and shut down to protect itself. Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E27 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive has detected the incoming voltage is too high. Fault – service needed Mains supply voltage too high Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E28 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive electronics are running too hot. Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E29 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive has detected the incoming voltage is too low. Fault – service needed Low mains supply voltage (brownout) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E3 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (4 lamp flashes))also shown as 4 lamp flashes The indoor fan is not running at the correct speed. Fault – service needed Faulty indoor fan motor Clean or check the return air filter is not clogged
E3 (Multi-split outdoor units (MRC)) The outdoor unit’s inverter (IPM) board has lost communication with the main outdoor control board. Fault – service needed Loose or damaged wiring between outdoor boards Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E3 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The indoor coil outlet temperature sensor (T2A) has failed. Minor fault Sensor open or short circuit Turn the system off at the isolator for 5 minutes, then restart it once
E3 (Ducted systems on LM7, LM24, LM-ZC, LR7, LC7, NEO and Que controllers (Classic, Classic 2, ESP Digital/Plus, ESP Platinum, Advance, Aires, QUE))also shown as E03 A room temperature sensor has failed (open or short circuit), so the system cannot read the room temperature properly. Minor fault Faulty wall controller or remote room sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E30 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive has locked itself out after repeated faults and needs to be reset and checked. Fault – service needed Repeated drive protection trips Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E31 (ESP Platinum and QUE single phase ducted systems) The compressor drive has reported an internal error. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E32 (ESP Platinum and QUE single phase ducted systems)also shown as E33 The system tripped on high or low refrigerant pressure measured by the drive’s pressure sensors (envelope protection). Fault – service needed Blocked outdoor coil or restricted airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E34 (ESP Platinum and QUE single phase ducted systems) The unit has reduced its output because the compressor drive is running hot (derating). Minor fault Hot weather and heavy use Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E35 (ESP Platinum and QUE single phase ducted systems) The unit has reduced its output because the suction pressure is low (derating). Minor fault Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
E36 (ESP Platinum and QUE single phase ducted systems) The unit has reduced its output because the condenser pressure is low (derating). Minor fault Very cold outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E37 (ESP Platinum and QUE single phase ducted systems) The unit has reduced its output because the condenser pressure is high (derating). Minor fault Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E38 (ESP Platinum and QUE single phase ducted systems) The unit has reduced its output to stay within its power limit (derating). Normal operation Heavy demand in extreme weather Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E39 (ESP Platinum and QUE single phase ducted systems) A defrost cycle took too long to complete and timed out. Minor fault Very cold or wet outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E4 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (5 lamp flashes))also shown as 5 lamp flashes The indoor room temperature sensor (T1) has failed (open or short circuit). Minor fault Faulty room temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E4 (Multi-split outdoor units (MRC)) An outdoor temperature sensor (coil T3, ambient T4, discharge T5 or indoor coil outlet pipe T2B) has failed. Minor fault Faulty temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E4 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The indoor coil outlet pipe temperature sensor (T2B) has failed. Minor fault Faulty pipe sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E4 (Ducted systems on LM7, LM24, LR7, LC7, NEO and Que controllers (Classic, Classic 2, ESP Digital/Plus, ESP Platinum, Advance, Aires, QUE; the QUE three phase table reads it as the indoor coil out sensor))also shown as E04 The indoor coil temperature sensor has failed (open or short circuit). Minor fault Faulty indoor coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E40 (ESP Platinum and QUE single phase ducted systems) The compressor drive is restarting too frequently, which points to an underlying problem. Fault – service needed Power supply interruptions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E41 (ESP Platinum, Advance, Aires and QUE ducted systems) The compressor drive’s internal DC voltage is too low. Fault – service needed Low or unstable mains supply Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E42 (Advance, Aires and QUE three phase ducted systems) The system shut down to protect the compressor because the evaporating pressure fell extremely low (envelope protection). Fault – service needed Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
E43 (Advance, Aires and QUE three phase ducted systems) The system shut down to protect the compressor because the compression ratio was too high (envelope protection). Fault – service needed Blocked outdoor coil in cooling Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E44 (Advance, Aires and QUE three phase ducted systems) The system shut down because the condensing pressure was too high (envelope protection). Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E45 (Advance, Aires and QUE three phase ducted systems) The system shut down because the compression ratio was too low (envelope protection). Fault – service needed Mild conditions with low load Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E47 (Advance, Aires and QUE three phase ducted systems) The compressor hit its torque limit and the system shut down to protect it. Fault – service needed Compressor under mechanical stress Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E5 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (6 lamp flashes))also shown as 6 lamp flashes The indoor coil temperature sensor (T2) has failed (open or short circuit). Minor fault Faulty evaporator coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E5 (Multi-split outdoor units (MRC)) The supply voltage to the outdoor unit is too high or too low. Fault – service needed Mains voltage problems (brownout or surge) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E5 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) An outdoor temperature sensor (T3 coil or TP discharge) has failed. Minor fault Faulty outdoor sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E5 (Classic (SRA/SRE/SRG), ESP Digital/Plus (SRD/SRV) and ESP Platinum ducted systems; QUE single phase shows E05 on the outdoor display)also shown as E05 The indoor and outdoor units have lost communication with each other. Fault – service needed Power interruption to the outdoor unit Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
E50 (Advance, Aires and QUE three phase ducted systems) The outdoor control board is not configured correctly for the unit. Fault – service needed Board replaced without correct setup Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E51 (Classic 2, Advance, Aires and QUE ducted systems (NEO, LR7-1, LC7-2 or Que controllers)) The indoor and outdoor units have lost communication with each other. Fault – service needed Damaged or loose communication cable between units Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
E52 (Classic 2, Advance, Aires and QUE ducted systems (NEO, LR7-1, LC7-2 or Que controllers)) The indoor unit has lost communication with the wall controller. Fault – service needed Loose or damaged controller cable Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E53 (QUE ducted systems with Que zoning (single and three phase)) The indoor unit has lost communication with the zone (VAV) module. Fault – service needed Loose or damaged zone module wiring Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E55 (Classic 2, Advance and Aires ducted systems (NEO, LR7-1 or LC7-2 wall controller)) The outdoor unit has lost communication with the building management system (BMS) interface. Minor fault Loose or damaged BMS wiring Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E56 (Classic 2, Advance and Aires ducted systems (NEO, LR7-1 or LC7-2 wall controller)) The system cannot find a master wall controller. Fault – service needed Wall controller not set as master Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E6 (Multi-split outdoor units (MRC)) The power factor correction (PFC) module in the outdoor unit has tripped a protection. Fault – service needed Power quality problems Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E6 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The indoor circuit board’s zero crossing check has failed (a power signal fault on the board). Fault – service needed Indoor control board fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E6 (Most ActronAir ducted systems (Classic, ESP Digital/Plus, ESP Platinum, Advance, Aires, QUE; LM7, LM24, LR7, NEO and Que controllers))also shown as E06 The compressor discharge temperature is too high, which often means the system is low on refrigerant. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E60 (Advance, Aires and QUE three phase ducted systems) The compressor drive has detected excessive current in a compressor phase and shut down. Urgent – turn it off Compressor winding or wiring fault Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E61 (Advance and Aires ducted systems) The compressor drive has lost one of the compressor’s output phases. Fault – service needed Loose or damaged compressor wiring Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E62 (Advance, Aires and QUE three phase ducted systems) The compressor drive’s internal DC bus voltage is too high. Fault – service needed Mains voltage surge Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E63 (Advance, Aires and QUE three phase ducted systems) The compressor drive’s internal DC bus voltage is too low. Fault – service needed Low or unstable mains supply Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E64 (Advance ducted systems) The compressor drive has lost track of the compressor rotor and stopped it. Fault – service needed Compressor drive fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E65 (Advance ducted systems) The current sensor for the compressor’s U phase has failed. Fault – service needed Faulty current sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E65 (Aires ducted systems) The compressor drive has detected a compressor phase loss fault. Fault – service needed Loose or damaged compressor wiring Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E66 (Advance ducted systems with the R-410A (Uno board) outdoor unit and QUE three phase systems)also shown as E66* The incoming AC supply voltage is imbalanced between phases or an input phase has been lost. Fault – service needed A phase lost at the switchboard Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E67 (Advance ducted systems with the R-410A (Uno board) outdoor unit and QUE three phase systems)also shown as E67* The compressor drive’s inverter has tripped a de-saturation (hardware overcurrent) protection. Fault – service needed Drive power electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E68 (Advance ducted systems) The current sensor for the compressor’s V phase has failed. Fault – service needed Faulty current sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E69 (Advance, Aires and QUE three phase ducted systems) The drive’s power factor correction (PFC-IGBT) module is running too hot. Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E7 (Serene (WRC/WRE) wall splits and multi-split indoor units (MRE/BRE)) The indoor unit’s display board has lost communication with the main indoor circuit board. Minor fault Loose or damaged display cable Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E7 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The indoor unit’s memory chip (EEPROM) has a fault. Fault – service needed Corrupted indoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E7 (Most ActronAir ducted systems (Classic, Classic 2, ESP Digital/Plus, ESP Platinum, Advance, Aires, QUE; LM7, LM24, LR7, NEO and Que controllers))also shown as E07 The outdoor coil temperature sensor has failed (open or short circuit). Minor fault Faulty outdoor coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E70 (Advance, Aires and QUE three phase ducted systems) The compressor drive has lost the compressor rotor position and stopped it. Fault – service needed Compressor drive fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E71 (Advance, Aires and QUE three phase ducted systems) The compressor motor temperature sensor (thermistor) has failed. Minor fault Faulty motor temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E72 (Advance, Aires and QUE three phase ducted systems) The drive’s precharge relay is stuck open, so the drive cannot power up properly. Fault – service needed Drive relay fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E73 (Advance and Aires ducted systems) The current sensor for the compressor’s W phase has failed. Fault – service needed Faulty current sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E74 (Advance and Aires ducted systems) The drive has tripped on IGBT overcurrent, which can point to a choke wiring problem or failure. Urgent – turn it off Choke wiring problem or choke failure Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E74 (QUE three phase ducted systems) The compressor drive has detected excessive current in a compressor phase and shut down. Urgent – turn it off Compressor winding or wiring fault Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E75 (Advance, Aires and QUE three phase ducted systems) The drive kept reducing compressor speed because of high phase current until it timed out (foldback timeout). Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E76 (Advance, Aires and QUE three phase ducted systems) The drive kept reducing output because its power module was too hot until it timed out (foldback timeout). Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E77 (Advance, Aires and QUE three phase ducted systems) The drive kept reducing output because of high AC input current until it timed out (foldback timeout). Fault – service needed Heavy demand in extreme weather Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E78 (Advance and Aires ducted systems) The drive’s power factor correction (PFC-IGBT) module temperature is abnormally low. Minor fault Very cold outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E78 (QUE three phase ducted systems) The drive’s automatic configuration communication has timed out. Fault – service needed Loose or damaged wiring between outdoor boards Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E79 (Advance and Aires ducted systems) The drive has tripped a hardware overcurrent (IPM) protection on the compressor. Urgent – turn it off Drive power electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E8 (Cascade (URC/CRE) and UltraSlim (URC/LRE) twin systems (indoor display, 9 lamp flashes))also shown as 9 lamp flashes The master and slave indoor units of a twin system have lost communication with each other. Fault – service needed Interconnecting cable fault between the twin indoor units Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E8 (Multi-split outdoor units (MRC)) The outdoor fan is not running at the correct speed. Fault – service needed Faulty outdoor fan motor Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E8 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The indoor fan controller is out of control (the fan is not responding correctly). Fault – service needed Faulty indoor fan motor Clean or check the return air filter is not clogged
E8 (ESP Digital/Plus, ESP Platinum, Advance, Aires and QUE ducted systems (not the original Classic series))also shown as E08 The outdoor discharge temperature sensor has failed (open or short circuit). Minor fault Faulty discharge sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E80 (Advance, Aires and QUE three phase ducted systems) The compressor motor temperature is too high. Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E81 (Advance, Aires and QUE three phase ducted systems) The compressor drive’s control board temperature is too high. Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E82 (Advance, Aires and QUE three phase ducted systems) The compressor drive’s power module temperature is too high. Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E83 (Advance, Aires and QUE three phase ducted systems) The drive’s power factor correction (PFC-IGBT) module temperature is too high. Fault – service needed Blocked outdoor unit airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E84 (Advance, Aires and QUE three phase ducted systems) Communication has been lost between two processors (DSP and PFC) inside the compressor drive. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E85 (Advance, Aires and QUE three phase ducted systems) Communication has been lost between the drive’s communications processor and its DSP. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E86 (Advance and QUE three phase ducted systems) The current drawn by the compressor phases is imbalanced. Fault – service needed Compressor winding fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E87 (Advance and QUE three phase ducted systems) The current in the drive’s three phase PFC circuit is imbalanced. Fault – service needed Uneven supply voltage between phases Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E88 (Advance ducted systems with the R-32 (Uno Pro board) outdoor unit, Aires and QUE three phase systems)also shown as E88** The compressor drive has a microelectronics or memory (EEPROM) fault. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E89 (Advance and QUE three phase ducted systems) The compressor motor ran over its speed limit and the drive shut it down. Fault – service needed Drive control fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E9 (Cascade (URC/CRE) and UltraSlim (URC/LRE) twin systems (indoor display, 10 lamp flashes))also shown as 10 lamp flashes Another indoor unit in the twin system has a fault. Fault – service needed A fault on the other indoor unit of the twin pair Check the other indoor unit’s display for its own fault code and look that code up
E9 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The main indoor circuit board has lost communication with the display board. Minor fault Loose or damaged display cable Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E9 (Classic (SRA/SRE/SRG) and ESP Digital/Plus (SRD/SRV) ducted systems with LM7 or LM24 wall controller) A refrigerant pressure switch has tripped on high or low pressure, or a power phase problem has been detected (phase faults on three phase units). Fault – service needed Blocked outdoor coil or restricted airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E90 (Advance, Aires and QUE three phase ducted systems) The drive is configured for the wrong compressor model. Fault – service needed Drive replaced without correct setup Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E91 (Advance, Aires and QUE three phase ducted systems) The temperatures measured inside the inverter are imbalanced. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E92 (Advance, Aires and QUE three phase ducted systems) The temperatures measured in the drive’s PFC circuit are imbalanced. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E93 (Advance and Aires ducted systems) The compressor motor temperature reading is abnormally low. Minor fault Very cold outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E94 (Advance and Aires ducted systems) The compressor drive’s board temperature reading is abnormally low. Minor fault Very cold outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E95 (Advance and Aires ducted systems) The drive’s power module temperature reading is abnormally low or its sensor has failed (open or short circuit). Minor fault Faulty temperature sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E96 (Advance ducted systems) The drive’s power factor correction (PFC-IGBT) module temperature is abnormally low. Minor fault Very cold outdoor conditions Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E96 (Aires ducted systems) The temperature sensing circuit for the drive’s PFC module has a malfunction. Minor fault Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E97 (Advance ducted systems) The drive’s communications analog to digital converter (ADC) has failed. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E97 (Aires ducted systems) A processor chip (IC) inside the compressor drive has reset unexpectedly. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E98 (Advance and Aires ducted systems) A current sensor or current sensing circuit in the compressor drive has failed. Fault – service needed Faulty current sensor in the drive Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E99 (Advance ducted systems) The compressor drive has tripped on compressor overload. Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
E99 (Aires ducted systems) The compressor drive has reported a malfunction outside the standard list. Fault – service needed Drive electronics fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
E99 (QUE single phase ducted systems) The system shut down on compressor envelope protection. Fault – service needed Operating pressures outside safe limits Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
EA (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The compressor has tripped its overload protection (recorded after 4 trips). Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
EB (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The inverter power module (IPM) has a malfunction. Fault – service needed Inverter module fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EC (Aurora (SWB) and Serene (WRC/WRE) wall splits and Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (7 lamp flashes))also shown as 7 lamp flashes The system has detected a possible refrigerant leak. Urgent – turn it off Refrigerant leak in the piping or coils Stop using the unit and switch it off at the isolator or breaker
EC (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The air clean function has a malfunction. Minor fault Air clean module fault Turn the system off at the isolator for 5 minutes, then restart. Cooling and heating usually still work while this fault is present.
EC07 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 12 lamp flashes The outdoor fan is running outside its normal speed range (some models). Fault – service needed Faulty outdoor fan motor Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
EC0D (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 14 lamp flashes The outdoor unit has reported a malfunction; the outdoor display carries the detailed code. Fault – service needed Any outdoor unit fault (pressure, temperature or drive protection) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
EC51 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 5 lamp flashes The outdoor unit’s memory chip (EEPROM) has a parameter error. Fault – service needed Corrupted outdoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EC52 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 5 lamp flashes The outdoor coil temperature sensor (T3) has failed (open or short circuit). Minor fault Faulty condenser coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EC53 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 5 lamp flashes The outdoor air temperature sensor (T4) has failed (open or short circuit). Minor fault Faulty outdoor ambient sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EC54 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 5 lamp flashes The compressor discharge temperature sensor (TP) has failed (open or short circuit). Minor fault Faulty discharge sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EC56 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes (free-match indoor units))also shown as 5 lamp flashes The evaporator coil outlet temperature sensor (T2B) has failed (open or short circuit). Minor fault Faulty pipe sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
ED (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The outdoor unit has a protection fault; the outdoor display carries the detailed code. Fault – service needed Any outdoor unit fault (pressure, temperature or drive protection) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
EE (Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (cassette and ducted units, 8 lamp flashes); shown as EE full water alarm on the WC-02 wired controller)also shown as 8 lamp flashes The condensate water level alarm has activated, meaning the drain system cannot get rid of water. Fault – service needed Blocked condensate drain Turn the unit off to stop further dripping
EF (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) A fault outside the standard list has been detected (other fault). Minor fault Miscellaneous indoor or outdoor fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH00 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as EH0A, 1 lamp flash The indoor unit’s memory chip (EEPROM) has a parameter error. Fault – service needed Corrupted indoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH03 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 4 lamp flashes The indoor fan is running outside its normal speed range (some models). Fault – service needed Faulty indoor fan motor Clean or check the return air filter is not clogged
EH0E (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes (cassette and ducted units))also shown as 13 lamp flashes The condensate water level alarm has activated, meaning the drain system cannot get rid of water. Fault – service needed Blocked condensate drain Turn the unit off to stop further dripping
EH0b (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 9 lamp flashes The two processor chips on the indoor unit have lost communication with each other. Minor fault Indoor control board fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH3A (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes (units with an external fan module))also shown as 4 lamp flashes The external fan module’s DC bus voltage is too low. Fault – service needed Low or unstable mains supply Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH3b (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes (units with an external fan module))also shown as 4 lamp flashes The external fan module’s DC bus voltage is too high. Fault – service needed Mains voltage surge Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH60 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 6 lamp flashes The indoor room temperature sensor (T1) has failed (open or short circuit). Minor fault Faulty room temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EH61 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 6 lamp flashes The indoor coil temperature sensor (T2) has failed (open or short circuit). Minor fault Faulty evaporator coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EHbA (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes (units with an external fan module)) The external fan module has lost communication with the indoor unit. Minor fault Loose or damaged fan module wiring Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
EL01 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 2 lamp flashes The indoor and outdoor units have lost communication with each other. Fault – service needed Damaged or loose interconnecting cable Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
EL0C (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 8 lamp flashes The system has detected a possible refrigerant leak (some models). Urgent – turn it off Refrigerant leak in the piping or coils Stop using the unit and switch it off at the isolator or breaker
F0 (Serene (WRC/WRE) wall splits and Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (some units, 1 lamp flash); also the outdoor display on Cascade, UltraSlim and UltraSlim R-32 systems)also shown as 1 lamp flash Overcurrent or overload protection has tripped. Urgent – turn it off Power surge or unstable supply voltage Turn the system off at the isolator for 5 minutes, then restart it once. If F0 returns, leave the system off.
F0 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The wired wall controller has lost communication with the indoor unit. Fault – service needed Loose or damaged controller cable Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F1 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (2 lamp flashes))also shown as 2 lamp flashes The outdoor air temperature sensor (T4) has failed (open or short circuit). Minor fault Faulty outdoor ambient sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F1 (Multi-split outdoor units (MRC)) The coil outlet temperature sensor for indoor unit A has failed. Minor fault Faulty pipe sensor on that indoor unit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F1 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The elevating fascia panel has not closed properly. Minor fault Something obstructing the panel Check nothing is stopping the fascia panel from closing fully
F2 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (3 lamp flashes))also shown as 3 lamp flashes The outdoor coil temperature sensor (T3) has failed (open or short circuit). Minor fault Faulty condenser coil sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F2 (Multi-split outdoor units (MRC)) The coil outlet temperature sensor for indoor unit B has failed. Minor fault Faulty pipe sensor on that indoor unit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F3 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (4 lamp flashes))also shown as 4 lamp flashes The compressor discharge temperature sensor (T5) has failed (open or short circuit). Minor fault Faulty discharge sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F3 (Multi-split outdoor units (MRC)) The coil outlet temperature sensor for indoor unit C has failed. Minor fault Faulty pipe sensor on that indoor unit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F4 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (5 lamp flashes))also shown as 5 lamp flashes The outdoor unit’s memory chip (EEPROM) has a parameter error. Fault – service needed Corrupted outdoor board memory Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F4 (Multi-split outdoor units (MRC)) The coil outlet temperature sensor for indoor unit D has failed. Minor fault Faulty pipe sensor on that indoor unit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F5 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (6 lamp flashes))also shown as 6 lamp flashes The outdoor fan is not running at the correct speed. Fault – service needed Faulty outdoor fan motor Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
F5 (Multi-split outdoor units (MRC)) The coil outlet temperature sensor for indoor unit E has failed. Minor fault Faulty pipe sensor on that indoor unit Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F6 (Cascade and UltraSlim free-match indoor units and multi-split indoor units (MRE/BRE) (7 lamp flashes))also shown as 7 lamp flashes The indoor coil outlet pipe temperature sensor (T2B) has failed (open or short circuit). Minor fault Faulty pipe sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F7 (Cascade slim cassettes with an auto-lifting panel (8 lamp flashes))also shown as 8 lamp flashes The auto-lifting panel has lost communication with the slim cassette unit. Minor fault Loose or damaged panel cable Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
F8 (Cascade slim cassettes with an auto-lifting panel (9 lamp flashes))also shown as 9 lamp flashes The auto-lifting panel mechanism is faulty. Minor fault Panel lifting motor fault Check nothing is caught in or hanging from the panel
F9 (Cascade slim cassettes with an auto-lifting panel (10 lamp flashes))also shown as 10 lamp flashes The auto-lifting panel has not closed properly. Minor fault Something obstructing the panel Check nothing is stopping the panel from closing fully
J0 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The evaporator coil temperature is too high and the unit has stopped to protect itself. Fault – service needed Restricted indoor airflow Clean or check the return air filter is not clogged
J1 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The condenser coil temperature is too high and the unit has stopped to protect itself. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
J2 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The compressor discharge temperature is too high and the unit has stopped to protect itself. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
J3 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The power factor correction (PFC) module in the outdoor unit has tripped a protection. Fault – service needed Power quality problems Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
J4 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The outdoor unit’s main board has lost communication with the compressor drive board. Fault – service needed Loose or damaged wiring between outdoor boards Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
J5 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The high pressure protection has tripped, usually because the outdoor unit cannot get rid of heat. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
J6 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The low pressure protection has tripped, usually because the system is low on refrigerant. Fault – service needed Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
J8 (Cascade (URC/CRE), UltraSlim (URC/LRE) and UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The incoming AC power voltage is outside safe limits and the unit has stopped. Fault – service needed Mains voltage problems (brownout or surge) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
LP (UltraSlim R-32 (URC/LRE/LRC) systems (outdoor unit display)) The unit has stopped because the outdoor temperature is too low for safe operation. Normal operation Extremely cold outdoor conditions Wait until the outdoor temperature rises, then restart the unit
P0 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (1 lamp flash))also shown as 1 lamp flash The inverter power module (IPM) has detected a fault or excessive current and shut the compressor down. Fault – service needed Inverter module fault Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P0 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The evaporator (indoor coil) temperature protection has tripped. Minor fault Blocked return air filter Clean or check the return air filter is not clogged
P1 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (2 lamp flashes))also shown as 2 lamp flashes The supply voltage to the unit is too high or too low. Fault – service needed Mains voltage problems (brownout or surge) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
P1 (Multi-split outdoor units (MRC): models MRC-100AS-4, MRC-110AS-5 and MRC-135AS-5 only) The high pressure protection has tripped, usually because the outdoor unit cannot get rid of heat. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P1 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The unit is in defrost or anti-cold-draught mode, which is normal operation rather than a fault. Normal operation Normal defrosting of the outdoor coil in cold weather Wait 5 to 15 minutes for the cycle to finish
P2 (Aurora (SWB) and Serene (WRC/WRE) wall splits (Aurora SWB52C and SWB70C only), Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and the UltraSlim R-32 outdoor display (3 lamp flashes))also shown as 3 lamp flashes The compressor (or on some models the inverter module) has overheated and the unit has shut down to protect it. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P2 (Multi-split outdoor units (MRC): models MRC-100AS-4, MRC-110AS-5 and MRC-135AS-5 only) The low pressure protection has tripped, usually because the system is low on refrigerant. Fault – service needed Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
P2 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The condenser temperature protection has tripped. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P3 (Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, 4 lamp flashes))also shown as 4 lamp flashes The unit has stopped because the outdoor temperature is too low for safe operation. Normal operation Extremely cold outdoor conditions Wait until the outdoor temperature rises, then restart the unit
P3 (Multi-split outdoor units (MRC)) The outdoor unit is drawing too much electrical current and has shut down to protect itself. Urgent – turn it off Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P3 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The compressor temperature protection has tripped. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P4 (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including compressor rotor position protection, and the UltraSlim R-32 outdoor display) and multi-split indoor units (MRE/BRE) (5 lamp flashes))also shown as 5 lamp flashes The inverter compressor drive has reported an error and stopped the compressor. Fault – service needed Compressor drive fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
P4 (Multi-split outdoor units (MRC); also shown as P4 (discharge pipe temperature protection) on the WC-02 wired controller) The compressor discharge temperature is too high and the unit has stopped to protect the compressor. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P5 (Multi-split systems (MRE/BRE indoor units, 6 lamp flashes))also shown as 6 lamp flashes Two indoor units are asking for opposite modes (one heating, one cooling), which the system cannot do at the same time. Normal operation Indoor units set to conflicting modes Set all indoor units to the same mode (all cooling or all heating) on their remotes
P5 (Multi-split outdoor units (MRC)) The condenser temperature is too high and the unit has stopped to protect itself. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P5 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The discharge high pressure protection has tripped. Fault – service needed Blocked or dirty outdoor coil Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P6 (Multi-split systems (MRE/BRE indoor units, 7 lamp flashes))also shown as 7 lamp flashes The outdoor unit has tripped on a high or low refrigerant pressure fault (the outdoor display shows J5 for high pressure or J6 for low pressure). Fault – service needed Blocked outdoor coil or restricted airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P6 (Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor display, 7 lamp flashes))also shown as 7 lamp flashes The compressor voltage protection has tripped. Fault – service needed Mains voltage problems (brownout or surge) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
P6 (Multi-split outdoor units (MRC)) The inverter power module (IPM) has tripped a protection and stopped the compressor. Fault – service needed Inverter module fault Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
P6 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The discharge low pressure protection has tripped, usually because the system is low on refrigerant. Fault – service needed Low refrigerant charge (possible leak) Clean or check the return air filter is not clogged
P7 (Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, 8 lamp flashes) and the UltraSlim R-32 outdoor display)also shown as 8 lamp flashes The outdoor inverter (IGBT) temperature sensor is faulty (open or short circuit). Minor fault Faulty IGBT temperature sensor Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
P7 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The over-voltage protection has tripped. Fault – service needed Mains supply voltage too high Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
P8 (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) The compressor overload protection has tripped. Fault – service needed Compressor working too hard due to blocked airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
PC00 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 7 lamp flashes The inverter power module has detected a fault or excessive current and shut the compressor down. Fault – service needed Inverter module fault Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
PC01 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 2 lamp flashes The supply voltage to the unit is too high or too low. Fault – service needed Mains voltage problems (brownout or surge) Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
PC02 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 3 lamp flashes The compressor or inverter module has overheated and the unit has shut down to protect itself. Fault – service needed Low refrigerant charge (possible leak) Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
PC03 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 7 lamp flashes The system has tripped on a high or low refrigerant pressure fault (some models). Fault – service needed Blocked outdoor coil or restricted airflow Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
PC04 (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)also shown as 5 lamp flashes The inverter compressor drive has reported an error and stopped the compressor. Fault – service needed Compressor drive fault Turn the system off at the isolator or breaker, wait 5 minutes, then restart it
PF (Systems with the WC-02 wired wall controller (Cascade and UltraSlim ducted and cassette units)) A fault has occurred elsewhere in the system; check the indoor or outdoor unit display for the detailed code. Minor fault Any indoor or outdoor unit fault not shown on the controller Check the indoor and outdoor unit displays for their own fault code and look that code up
dF (Serene Series 2 wall split indoor units (also shown as dEF on ducted outdoor displays)) The unit is running a normal defrost cycle in heating mode, not a fault. Normal operation Normal defrosting of the outdoor coil on cold mornings Wait 5 to 15 minutes for the defrost cycle to finish

Codes that mean switch the system off

If your ActronAir unit shows EC, F0, P3, EL0C, E60, E74, E74, E79, turn the system off at the isolator and leave it off. These faults involve the compressor, refrigerant or electrical protection, and running the unit can cause further damage.

The most serious ActronAir fault codes explained

What does ActronAir fault code EC mean? (Aurora (SWB) and Serene (WRC/WRE) wall splits and Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (7 lamp flashes))

The system has detected a possible refrigerant leak.

Likely causes:

  • Refrigerant leak in the piping or coils
  • Faulty leak detection sensor

Safe checks before you call:

  • Stop using the unit and switch it off at the isolator or breaker
  • Open windows to ventilate the room
  • Do not use open flames near the indoor unit

What does ActronAir fault code F0 mean? (Serene (WRC/WRE) wall splits and Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (some units, 1 lamp flash); also the outdoor display on Cascade, UltraSlim and UltraSlim R-32 systems)

Overcurrent or overload protection has tripped.

Likely causes:

  • Power surge or unstable supply voltage
  • Compressor or fan motor drawing excess current
  • Electrical fault on the outdoor unit

Safe checks before you call:

  • Turn the system off at the isolator for 5 minutes, then restart it once. If F0 returns, leave the system off.

What does ActronAir fault code P3 mean? (Multi-split outdoor units (MRC))

The outdoor unit is drawing too much electrical current and has shut down to protect itself.

Likely causes:

  • Compressor working too hard due to blocked airflow
  • Power supply problem
  • Failing compressor

Safe checks before you call:

  • Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
  • Clean or check the return air filter is not clogged
  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code EL0C mean? (Cascade R-32 (URC/CRC) and UltraSlim R-32 (URC/LRE/LRC) systems; Serene Series 2 R-32 wall splits show the same codes)

The system has detected a possible refrigerant leak (some models).

Likely causes:

  • Refrigerant leak in the piping or coils
  • Faulty leak detection sensor

Safe checks before you call:

  • Stop using the unit and switch it off at the isolator or breaker
  • Open windows to ventilate the room
  • Do not use open flames near the indoor unit

What does ActronAir fault code E60 mean? (Advance, Aires and QUE three phase ducted systems)

The compressor drive has detected excessive current in a compressor phase and shut down.

Likely causes:

  • Compressor winding or wiring fault
  • Compressor drive fault
  • Compressor working too hard due to blocked airflow

Safe checks before you call:

  • Look at the outdoor unit and make sure leaves, grass or objects are not blocking the airflow (do not open the unit)
  • Clean or check the return air filter is not clogged
  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E74 mean? (Advance and Aires ducted systems)

The drive has tripped on IGBT overcurrent, which can point to a choke wiring problem or failure.

Likely causes:

  • Choke wiring problem or choke failure
  • Drive power electronics fault
  • Compressor winding fault

Safe checks before you call:

  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E79 mean? (Advance and Aires ducted systems)

The drive has tripped a hardware overcurrent (IPM) protection on the compressor.

Likely causes:

  • Drive power electronics fault
  • Compressor winding fault
  • Failing compressor

Safe checks before you call:

  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E0 mean? (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (1 lamp flash))

The indoor unit’s memory chip (EEPROM) has a parameter error.

Likely causes:

  • Corrupted indoor board memory
  • Indoor control board fault

Safe checks before you call:

  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E1 mean? (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems (indoor and outdoor displays, including the UltraSlim R-32 outdoor display), multi-split indoor units (MRE/BRE) (2 lamp flashes) and the WC-02 wired controller)

The indoor and outdoor units have lost communication with each other.

Likely causes:

  • Damaged or loose interconnecting cable
  • Power interruption to the outdoor unit
  • Indoor or outdoor board fault

Safe checks before you call:

  • Check the outdoor unit isolator switch (next to the outdoor unit) is switched on
  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E3 mean? (Aurora (SWB) and Serene (WRC/WRE) wall splits, Cascade (URC/CRE) and UltraSlim (URC/LRE) split ducted and cassette systems and multi-split indoor units (MRE/BRE) (4 lamp flashes))

The indoor fan is not running at the correct speed.

Likely causes:

  • Faulty indoor fan motor
  • Fan obstruction
  • Indoor control board fault

Safe checks before you call:

  • Clean or check the return air filter is not clogged
  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E8 mean? (Cascade (URC/CRE) and UltraSlim (URC/LRE) twin systems (indoor display, 9 lamp flashes))

The master and slave indoor units of a twin system have lost communication with each other.

Likely causes:

  • Interconnecting cable fault between the twin indoor units
  • Indoor PCB fault

Safe checks before you call:

  • Turn the system off at the isolator or breaker, wait 5 minutes, then restart it

What does ActronAir fault code E9 mean? (Cascade (URC/CRE) and UltraSlim (URC/LRE) twin systems (indoor display, 10 lamp flashes))

Another indoor unit in the twin system has a fault.

Likely causes:

  • A fault on the other indoor unit of the twin pair
  • Communication fault between the twin units

Safe checks before you call:

  • Check the other indoor unit’s display for its own fault code and look that code up

Fault confirmed? Here is what to do next

A fault code is the starting point, not the fix. Start here:

Call us on 08 8296 7888 or book online and we will call or text you back ASAP.

Sources for this page

Every ActronAir code above is checked against these Australian documents. Open them yourself to verify anything on this page:

ActronAir fault code FAQs

Where do I find the fault code on a ActronAir air conditioner?

Check the remote or wall controller display first. Some models flash the indoor unit’s lamps in a pattern instead; the table above lists documented lamp patterns alongside their codes. If nothing is showing, the code may only appear while the fault is active.

Can I clear a ActronAir fault code myself?

You can reset the system by turning it off at the isolator or breaker for five minutes. If the code stays gone, it was a one-off. If it returns, the fault is real and needs a licensed technician, and repeated resets can cause further damage on compressor or refrigerant faults.

Does a ActronAir fault code mean I need a new air conditioner?

Usually not. Most codes point to repairable faults like sensors, fan motors or drainage. Our fault find gives you an honest verdict either way, and the fee is credited if you repair with us.

Are these ActronAir fault codes correct for Australian models?

Yes. Every code on this page was checked against Australian documentation (docs.actronair.com.au, actronair.com.au, valleyairconditioning.com.au), not overseas lists, because the same code can mean different things in different markets. Meanings still vary between model series, so treat this page as reference and cross-check your unit’s manual.

Fault codes for other brands

Not a ActronAir? Every brand below follows the same format: the documented Australian codes, what each one means, how serious it is and what is safe to check yourself.

Mitsubishi Electric codes have their own library: Mitsubishi Electric fault codes. Or start from the full fault code lookup, which covers more than 1,000 codes across 15 brands sold in Australia.

Written by Oliver Hastings, T&K Airpower. Last updated 14/09/2026. Compiled from Australian sources including docs.actronair.com.au, actronair.com.au, valleyairconditioning.com.au, airconditioningmackay.com.au, so you can check every code against the official documentation. Fault code meanings vary between model series and controllers, so treat this page as reference only and never remove panels or work on the refrigeration or electrical parts of the system yourself.

T&K Airpower - Air Conditioner and Electrician Repair experts in Adelaide

Established, Local, and Accountable

We’ve been working in Adelaide homes for over 30 years.

Every job is done by our own technicians, employed, not subcontracted, so the person on your roof or at your switchboard is accountable for the work. We back it with a lifetime workmanship warranty, and we’ll be here to stand behind it long after the job is done.

ExcellentGoogle star 1Google star 2Google star 3Google star 4Google star 54.9671 reviews
4.9Google star 1Google star 2Google star 3Google star 4Google star 5
Excellent671 reviews
Posted on Google Google
Kaye Cleave profile picture
Kaye Cleave
81 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Great service and professional staff. Thank you T& K Airpower. I'm very happy with my new air-conditioner and would highly recommended your company

Owner's reply
Thank you, Kaye! We're thrilled you're happy with your new air-conditioner and appreciate your kind recommendation. It was a pleasure assisting you! Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Boti Nagy profile picture
Boti Nagy
140 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Been having my home air conditioning serviced by T&K for years and always impressed with how this company operates. From booking an appointment with a repairman to job completion, this is a truly professional operation. But it hasn't lost the human touch. To my surprise and delight, my repairman Daniel rang to inform me he might be later than anticipated because the job he was completing was taking longer. He wasn't that late in the end and was friendly, genial and, most importantly, efficient and professional. Stayed true to the quoted price too, which didn't break the bank. Highly recommend T&K.

Owner's reply
Thank you so much for your review! Means the world to us hearing great feedback about our team! I will pass this on to Dan and the office Team 😊
Posted on Google Google
Jan Sutherland profile picture
Jan Sutherland
515 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
Quick, efficient and well priced. Technician was very polite, knowledgeable and completed the task with minimal fuss or disruption. Will definitely use this company in the future.

Owner's reply
Thank you, Jan! We're delighted to hear about your positive experience with our technician. We look forward to assisting you again whenever you need us. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Kosta Sotiropoulos profile picture
Kosta Sotiropoulos
561 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+2
As Director of CS Real Estate managing a Property Portfolio, one of our business objectives is that we only partner with quality suppliers / tradespeople. Working with high performing and reputable businesses is nonnegotiable. In late 2024 I contacted T&K Airpower for two separate maintenance jobs. From the moment I made contact with them, I found them to be extremely responsive, reliable and most importantly experts in what they do. There quotes and pricing is very competitive. And further to that, with each job I received a detailed invoice and photos of the works undertaken. I've attached some pictures of the new PC Board installed along with the new wall controller. I wouldn't hesitate recommending T&K Airpower, Cindy, Julie and the entire team do a great job. As a customer, I know my landlords are in great hands. Thank you to the team at T&K Airpower.

Owner's reply
Thank you, Kosta, for your thoughtful review and kind words about our team! We're thrilled to hear about your positive experience and look forward to continuing to support your property portfolio needs. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Aaron Albino profile picture
Aaron Albino
567 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+1
The guys were half an hour earlier than expected. Although it was nearly two weeks from when I put the warranty claim in with Hitachi.They were very thorough in their inspection and completely contradictory to the installers opinion who said it was a fault with the unit itself. The problem is still unresolved !

Owner's reply
We're sorry to hear this, Aaron. Please contact our customer service so we can assist you further and help resolve the issue promptly. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Davin & Jodie Pickard profile picture
Davin & Jodie Pickard
631 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+1
Excellent communication and on site service

Owner's reply
Thank you, Davin and Jodie, for your kind words! We're thrilled to hear you enjoyed our communication and on-site service. Your feedback motivates us to keep delivering quality service. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
T & J Air Conditioning profile picture
T & J Air Conditioning
792 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
+0
T & K were very professional. They handled our warranty claim with Mitsubishi Electric within a few days. The technician Nathan was great to deal with and communicated well.

Owner's reply
Thank you, Tom! We're glad to hear Nathan and the team at T & K provided you with excellent service. Your satisfaction with our warranty process means a lot to us.

(Translated by Google, see original)
Posted on Google Google
Charles Bartlett profile picture
Charles Bartlett
0 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Most excellent thorough friendly service. Makes a nice change from what you get elsewhere.
Posted on Google Google
Larry Rawlins profile picture
Larry Rawlins
1 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service, Ciaran was a very friendly and knowledgeable technician.
Posted on Google Google
Gilbertt Kat profile picture
Gilbertt Kat
4 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Cieran did our air conditioner service today. Very efficient, lovely guy, no fuss, explained thoroughly about the status of my unit. Thoroughly recommend!!

Owner's reply
Hi Gilbertt! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Ciaran got your air conditioning servicing sorted in Tusmore. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lucia Puzella profile picture
Lucia Puzella
5 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We had our solar panel's serviced on the 9/9/26 by Tristan, I was extremely impressed and happy with his professionalism. We also have our air-conditioning service with them. I would highly recommend them, that's why they deserved a 5 star. Thankyou T&K Air-conditioning and Electrical.

Owner's reply
Hi Lucia! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lyn and Wolfgang Zeidler profile picture
Lyn and Wolfgang Zeidler
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Efficient timely service

Owner's reply
Hi Lyn! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mario Pepicelli profile picture
Mario Pepicelli
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby was excellent, a really skilled tradesman. Worked out the issue with the air conditioner explained the options available. Once I selected the option he carried out the repair works.

Owner's reply
Hi Mario! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Barbara Isaacson profile picture
Barbara Isaacson
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Extremely happy, very thorough and friendly been using T&K Airpower for some 20 years plus, and have never had to complain about their service. Had a Solar Health Check done, and an Electrical Switch Board Upgrade that was badly needed, service was second to none, highly recommend. Price all up was good, and peace of mind guaranteed. 😀😀

Owner's reply
Thanks so much for your kind words! Have a lovely weekend! 👍😁
Posted on Google Google
Jamin Stojsavljevic profile picture
Jamin Stojsavljevic
7 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great experience. 1st place I’ll call now for repairs or a new system. Excellent technical knowledge, friendly, answered all of my questions. Fix and upgrade of my existing system was well done and installers were considerate, friendly and knowledgeable.

Owner's reply
Hi Jamin! Really appreciate the kind words, reviews like this mean a lot to us. Glad Jacob could look after your air conditioning repairs in WALKERVILLE. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Paul Maschgan profile picture
Paul Maschgan
10 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
If you're looking for a company that provides excellent communication, tradespeople who arrive on time, outstanding workmanship (thanks Tristan & Jacob) and leave everything clean and tidy then T & K Airpower is the company you are looking for. From my first contact with the office staff through to the completion of the work, the entire process was professional and hassle free. Nothing was too much trouble, and the team was friendly, knowledgeable, and happy to answer any questions. After reading the reviews before choosing T & K Airpower, I had high expectations, and I am pleased to say they were spot on. I would not hesitate in recommending them to anyone looking for quality air conditioning service and installation.

Owner's reply
Thank you so much, Paul, for your thoughtful feedback! We're thrilled to hear that Tristan, Jacob, and the team delivered a seamless experience. Your recommendation means a lot to us. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888

(Translated by Google, see original)
Posted on Google Google
Ben Nicholls profile picture
Ben Nicholls
11 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Always great service and advice from the T&K AirPower crew. Been using them forever, never any issues

Owner's reply
Hi Ben! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Ciaran got your electrical servicing sorted in Hampstead Gardens. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Bernard McCallum profile picture
Bernard McCallum
11 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Last week we had a replacement air conditioning system installed by T&K. Technicians Oliver/Kieran and Noah attended all day Wednesday 21/2/24. Oliver attended Friday 23/2/24. The work performed was outstanding. My wife and I rate very highly the service provided before the installation and during the installation. Should you consider utilising T&K you won’t regret it. What we rate very highly was the professionalism and meticulous care taken.

Owner's reply
Hi Bernard! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Malcolm Skilton profile picture
Malcolm Skilton
12 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I frequently base my assessment of any service provider on first contact. In the case of T&K Airpower Air Conditioning and Electrical, first contact was very positive. The quote I received was very reasonable (especially with the seniors discount), and I accepted that quote without needing to go to any other providers. The service tech (Nathan) arrived when scheduled and was very polite and helpful. He completed the required work efficiently, and within a very reasonable time frame. I would no hesitation in useing this company again.

Owner's reply
Hi Malcolm! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Nathan got your air conditioning servicing sorted in Craigmore. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Meg Michell profile picture
Meg Michell
14 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Fabulous service

Owner's reply
Hi Meg! Thanks so much for the great review, it genuinely means a lot to the team. So glad Ciaran could help you out with your air conditioning servicing in North Adelaide. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Michael Cusack profile picture
Michael Cusack
14 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
The guys were great. Very professional and personable. They worked hard and cleaned up before they left. Highly recommended and I would highly recommend them. So good these days to get prompt and professional help.

Owner's reply
Hi Michael! Really appreciate the kind words, reviews like this mean a lot to us. Glad Oliver could look after your air conditioning installation in Birdwood. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Rosslyn Eftimiou profile picture
Rosslyn Eftimiou
15 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Ciaran was friendly and very professional. Excellent service

Owner's reply
Hi Rosslyn! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Jodie Bradbrook profile picture
Jodie Bradbrook
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
This business has exceptional customer service and lovely technicians. They do quality work and are great to deal with. Highly recommend.

Owner's reply
Hi Jodie! Thanks so much for the great review, it genuinely means a lot to the team. So glad Tristan could help you out with your air conditioning repairs over in Richmond. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
ZoZo's YouTube Channel profile picture
ZoZo's YouTube Channel
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Prompt and professional service

Owner's reply
Hi ZoZo's! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Peter Dalton profile picture
Peter Dalton
21 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We were being gassed by an old Daiken air conditioner losing its refrigerant and causing headaches in our Study. We called T&K AirPower through our RAA membership, their technician / salesman Toby arrived promptly and was able to spot the problem then present options which became a reasonably priced new Mitsubishi unit which we coupled with another unit for our adjacent Guest Bedroom working off the same fan coil unit. He spent time on a solution for an on roof mounted unit for our Family Room. The installation team Oliver, Luke and Giaran did a great install including a new electrical circuit. Definitely a 5 Star review but for a couple of old dodgy baby boomers, I was impressed with the ease of communication and professionalism.

Owner's reply
Hi Peter! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Sam Catley profile picture
Sam Catley
24 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
A great big thankyou to Toby, Oliver, Nick, Noah & the T&K Air Team for your brilliant service. You were professional, knowledgeable & surpassed our expectations. We are thrilled with our new ducted aircon.

Owner's reply
Hi Sam! Thank you for the lovely review, the team was stoked to see it. So good to hear Noah took care of your air conditioning installation for you in Prospect. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Winston Head profile picture
Winston Head
25 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby is a very knowledgeable, he explained many things about our AC that we had no idea about. He suggested several things that would make our unit run better and more efficiently, saving $$$ and work. We have no hesitation in recommending Toby for any AC service.

Owner's reply
Hi Winston! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Tobias got your air conditioning servicing sorted in Highbury. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Lyn Jefferies profile picture
Lyn Jefferies
28 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service & prompt attention. Good price for a country job too.

Owner's reply
Thank you, Lyn! We're thrilled you were pleased with our service and pricing. Your feedback means a lot to us!
Posted on Google Google
Bob Aston profile picture
Bob Aston
28 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service. Kieran was right on time, went about the job in an efficient and organised way and completed it within the given timeframe. Cost as expected. We would recommend the company any time.

Owner's reply
Thank you, Bob! We're thrilled to hear about your positive experience with Kieran. Your recommendation means a lot to us and we look forward to assisting you again in the future. Thanks, Oliver and the T&K Airpower Team! 08 8296 7888
Posted on Google Google
Sally Huefner profile picture
Sally Huefner
30 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Last thing you need mid winter is the heating to stop working so a call to T&K and Toby was out to diagnose and fix the system. Great service, quickly found the problem, had the part on the van and soon it was warm again inside. Highly recommended Toby and the team at T&K AirPower.

Owner's reply
Hi Sally! Thanks so much for the great review, it genuinely means a lot to the team. So glad Tobias could help you out with your air conditioning repairs over in Hazelwood Park. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Daniel Dieckmann profile picture
Daniel Dieckmann
30 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Happy with Jacob on a/c service and replacement 2 fan motors. All working well.

Owner's reply
Hi Daniel! Thanks so much for the great review, it genuinely means a lot to the team. So glad Jacob could help you out with your air conditioning repairs in Glengowrie. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mike Munday profile picture
Mike Munday
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We contacted T&K Airpower to arrange some repairs on our Temperzone air conditioner. I called them on a Thursday and they had a technician (Toby) available on the following Monday morning 3 August. Our controller was not working properly and stopped working altogether the day before Toby came. When he arrived he checked what we wanted done and which we discussed with him. He said he wanted to have a look at the unit outside to see if he could at least get the air conditioner working. As he was doing this a solenoid fused with a large bang so he couldn’t do anything else until that part was replaced. He contacted the office to arrange a quote so they could commence sourcing the parts. The controller took longer than expected to source and the job was booked in for Friday 14 August but due to another job being postponed we had our job brought forward to Wednesday 12 August which was most appreciated due to having a very cold house during this period. The technician that completed our work was Artie and he was absolutely fantastic. When he arrived we went through everything that had to be done which we were advised would take up to about 5 hours. The new controller had to be completely re wired, the new solenoid fitted and the whole system serviced. We also replaced 3 hard wired fire alarms replaced. Artie was very tidy and respectful and polite in every way. We would request his services if that was possible should we have any further issues that need attention. Also the young ladies in the office being Alicia and Ebony were also very helpful and courteous every time I dealt with them on the phone. The total cost was just over $2300 which we thought was reasonable for the efficiency and the job being completed by a quality technician in Artie.

Owner's reply
Hi Mike! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Travers Gebler profile picture
Travers Gebler
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
On-time, very easy to deal with. Enthusiastic & polite crew. Recommend for sure.

Owner's reply
Hi Travers! Thank you for the lovely review, the team was stoked to see it. So good to hear Noah took care of your air conditioning installation for you in Kidman Park. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Chris Boyd profile picture
Chris Boyd
31 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Excellent communication, professional conduct, and reasonable price

Owner's reply
Hi Chris! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tristan could look after your air conditioning servicing in Virginia. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Petre Thorn profile picture
Petre Thorn
32 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby was on time, professional and knowledgeable.

Owner's reply
Hi Petre! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Phil Bancroft profile picture
Phil Bancroft
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Arrived on time. Very friendly. Explained everything. Always very happy.

Owner's reply
Hi Phil! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Kate G profile picture
Kate G
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Nathan was efficient, friendly and provided useful information. Thanks

Owner's reply
Hi Kate! Thanks so much for the great review, it genuinely means a lot to the team. So glad we could help you out. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
babis babas profile picture
babis babas
35 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We could not be happier. Great service and our system has never worked so well before! Thanks guys.

Owner's reply
Hi babis! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
yueqiang zhang profile picture
yueqiang zhang
36 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Good service. Thanks Toby and T&K. Will be looking for some discounts for next service

Owner's reply
Hi yueqiang! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Angie Evans profile picture
Angie Evans
40 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Nathan arrived promptly, was friendly, completed the task required and provided information for future work. Pleased we chose T&K

Owner's reply
Hi Angie! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Mark Seatree profile picture
Mark Seatree
40 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Marty is a legend!

Owner's reply
Hi Mark! Thanks heaps for taking the time to leave us a review, we really appreciate it. Great to hear Martin got your air conditioning repairs sorted in Rostrevor. Give us a bell on 08 8296 7888 anytime you need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Maris Javier profile picture
Maris Javier
41 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Toby is an excellent worker. He was respectful and was very efficient. I would say one of the best I've dealt with. Thank you Toby for your competence and professionalism!

Owner's reply
Hi Maris! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Volker Trede profile picture
Volker Trede
42 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Quick turn around, excellent communication. Will use again.

Owner's reply
Hi Volker! Really appreciate the great review, thank you. So glad you were happy with the team, and don't hesitate to give us a call on 08 8296 7888 anytime. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Ken AY profile picture
Ken AY
42 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Used them to investigate an issue with a ducted AC system, attended by professional and experienced technicians who were able to quickly identify and fix the problem.

Owner's reply
Hi Ken! Thank you for the lovely review, it means a lot to us. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
jo Stone profile picture
jo Stone
45 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Amazing service. Excellent and trustworthy staff. Highly recommend. Service was easy and delivered with quality. Thank you

Owner's reply
Hi jo! Thank you for the lovely review, the team was stoked to see it. So good to hear Tobias took care of your air conditioning installation for you in Panorama. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Bianca Davidson profile picture
Bianca Davidson
45 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Lovely experience with technician Tristan. He walked me through every step, explained what would benefit my split system and gave me a run down of all my options.

Owner's reply
Hi Bianca! Thank you for the lovely review, the team was stoked to see it. So good to hear Tristan took care of your air conditioning servicing for you in Ingle Farm. Give us a call anytime on 08 8296 7888 if you ever need us. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Adrian Hocking profile picture
Adrian Hocking
46 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Absolutely Excellent Service and VERY HAPPY With the price. Service man was very nice and very polite. Thank you so much...

Owner's reply
Hi Adrian! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tristan could look after your air conditioning repairs in Craigmore. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Michael Bowes profile picture
Michael Bowes
47 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Excellent and honest service from Marty

Owner's reply
Hi Michael! Really appreciate the kind words, reviews like this mean a lot to us. Glad Martin could look after your air conditioning repairs in Belair. Do not hesitate to call us on 08 8296 7888 if you ever need us again. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Kerry Leaver profile picture
Kerry Leaver
48 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Received fantastic service, advice and support from Toby today. He communicated really well, spent time explaining what the issues were and what my options were. Then the replacement parts I needed were couriered over while Toby waited and my heating was working before he left. So efficient! He also spotted that my smoke alarm was expired which I had not asked him to check.

Owner's reply
Hi Kerry! Really appreciate the kind words, reviews like this mean a lot to us. Glad Tobias could look after your air conditioning repairs in Somerton Park. We are always here on 08 8296 7888 if you need anything down the track. Cheers, Oliver and the T&K Airpower team
Posted on Google Google
Tom profile picture
Tom
49 days ago
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
We initially had a temporary repair of our old air conditioner. That worked well but a new one was clearly the way to go. The service was uniformly prompt and outstanding. Tobi deserves particular credit for his professional, thorough and non-pushy contribution. Highly recommended. Tom Stubbs

Owner's reply
Hi Tom! Thanks heaps for the kind review, we really appreciate you taking the time. Glad we could get you sorted, and give us a bell on 08 8296 7888 if you ever need a hand. Cheers, Oliver and the T&K Airpower team
Verified by Trustindex
Trustindex verified badge is the Universal Symbol of Trust. Only the greatest companies can get the verified badge who has a review score above 4.5, based on customer reviews over the past 12 months. Read more
null

With Over 30 Years of Experience, You Can Trust Our Certified Technicians To Do The Job Right The FIRST TIME for your air conditioner and electrician needs.

null

Honest Advice on Your Home's Comfort, Energy and Safety

Every price and answer on this page comes from the same pricing and diagnostics our own technicians use, so what you see is a genuine indication, not a teaser.

Where an upgrade is genuinely needed, we’ll explain why in plain terms and set out your best option. No pressure, no unnecessary work.

We only recommend it when it improves safety, reliability or long-term performance.

We’ll call or text you back ASAP!

Bright green logo with sunburst design

Service Area

null

Servicing Adelaide Homes and Surrounding Suburbs

We provide residential electrical energy solutions and upgrades across metropolitan Adelaide, including inner eastern, western and southern suburbs