Adelaide's Mitsubishi Electric Air Conditioner Service and Repair Specialists
30 years experience with Mitsubishi Electric products!
Adelaide’s only warranty agent for Mitsubishi Electric VRF City Multi units!
Mitsubishi Electric specialists for troubleshooting and repairs!
Authorised Warranty Repairers in Adelaide for Leading Air Conditioning Brands
Mitsubishi Electric Air Conditioner Repairs and Service in Adelaide
Mitsubishi air conditioner not working? T&K Airpower has been a Mitsubishi Electric warranty agent in Adelaide since 1999. Our own employed technicians repair and service Mitsubishi Electric split systems, ducted systems and VRF City Multi units, using genuine parts, and we fix what is broken before anyone talks about replacing it. Call 08 8296 7888 or book a repair online.
Mitsubishi Electric is one of the most well-regarded air conditioning products within the air conditioning industry. Beginning in the 1960s, Mitsubishi Electric has specialised in the manufacture of a wide range of domestic and commercial air conditioning products for the Australian market. From small domestic hi-wall and Mr. Slim ducted systems to large commercial VRF air conditioning units Mitsubishi Electric has an extensive range to suit almost any need.
T&K Airpower began working with Mitsubishi Electric in 1999 as the warranty agent of choice, repairing air conditioning units throughout Adelaide and South Australia, within the 5 year warranty period. Now, with nearly 30 years of experience with Mitsubishi Electric products, we have the extensive skills and product knowledge to become the only warranty agent for Mitsubishi Electric VRF City Multi units in Adelaide.
To maintain our authority within the industry as Mitsubishi Electric specialists, all T&K Airpower technicians are trained regularly in the Mitsubishi Electric, Adelaide training room. Specialist courses are also undertaken in Sydney, specifically on the VRF City Multi air conditioning systems.
Is your Mitsubishi Electric Air Conditioner Not Working?
Ensuring you have the right air conditioning technician for your air conditioning brand makes a world of difference to the quality of your air conditioner repairs and also your hip pocket! With 30 years of experience in repairing Mitsubishi Electric air conditioners, you can trust that we know just about everything there is to know about your unit. You will get sound advice based on thorough diagnostics and extensive product knowledge. If your system has broken down at home, see our air conditioning repairs in Adelaide for fast, repair-first service.
Mitsubishi Electric Fault Code Guides
Seeing an error code on your Mitsubishi Electric air conditioner? Find what each code means and what to do next in our guides below.
| Code | What it means | How serious |
|---|---|---|
| E0 | The wall or remote controller is not transmitting its signal to the indoor unit properly. | Minor |
| E1 | The control board inside the wall or remote controller has developed a fault. | Minor |
| E2 | The indoor unit has detected it is overheating. | Major |
| E3 | The control board inside the wall or remote controller has failed or lost communication with the indoor unit. | Minor |
| E4 | The indoor unit is not receiving the signal from the wall or remote controller. | Minor |
| E5 | The wall or remote controller and the indoor unit have stopped transmitting to each other correctly. | Minor |
| E6 / E7 | The indoor and outdoor units have stopped communicating with each other. | Major |
| E8 | The system has detected an electrical overcurrent and shut down to protect itself. | Urgent |
| E9 | The control system inside the indoor unit has developed an error. | Major |
| EE | The indoor and outdoor units cannot communicate with each other. | Major |
| F1 | The high pressure sensor has developed an error. | Major |
| F2 | The low pressure sensor has developed an error. | Major |
| F3 | The temperature sensor on the outdoor unit's coil has developed an error. | Major |
| F4 | The indoor unit's fan motor has locked up and cannot spin. | Major |
| F5 | The outdoor unit's fan motor has locked up and cannot spin. | Major |
| F6 | The system has detected an abnormally low temperature at the compressor outlet. | Major |
| F7 | The system has detected an abnormally high temperature at the compressor outlet. | Major |
| F8 | The outdoor unit has shut down to protect itself from abnormally high refrigerant pressure. | Major |
| F9 | The system has shut down to protect itself from abnormally low refrigerant pressure. | Major |
| Fb | The indoor unit's control system has developed an internal error, such as a memory error. | Major |
| H1 | The indoor and outdoor units cannot communicate with each other. | Major |
| P1 | The sensor that measures the air being drawn into the indoor unit has developed a fault. | Major |
| P2 | The temperature sensor on the indoor unit's pipework (TH2) has developed a fault. | Major |
| P3 | The temperature sensor on the outdoor unit's pipework has developed a fault. | Major |
| P4 | The sensor that monitors the condensate drain has developed a fault. | Major |
| P5 | The pump that removes condensate water from the indoor unit has developed a fault. | Major |
| P6 | The system has shut down to protect itself from freezing up or overheating. | Major |
| P7 | The outdoor unit's heat exchanger is overheating. | Major |
| P8 | The indoor unit has not heated or cooled within the expected time, which usually means the compressor is not running; the underlying fault sits with the outdoor unit. | Major |
| P9 | The temperature sensor on the indoor unit's pipework (TH5) has developed a fault. | Major |
| PA | The compressor has been stopped by a forced compressor error. | Urgent |
| PB | The indoor unit's fan motor has developed a fault. | Major |
| U1 | The system has shut down to protect itself from abnormally high pressure or overheating. | Major |
| U2 | The system has detected an abnormally high compressor outlet temperature, often because refrigerant is low. | Major |
| U3 | One or more temperature sensors on the outdoor unit have failed with an open or short circuit. | Major |
| U4 | One or more temperature sensors on the outdoor unit have failed with an open or short circuit. | Major |
| U5 | The system has shut down because the heat sink that cools the inverter electronics in the outdoor unit has run too hot. | Major |
| U6 | The compressor has been stopped by an overcurrent trip or a fault in the outdoor unit's power module. | Urgent |
| U7 | The system has detected abnormal superheat caused by a low compressor outlet temperature. | Major |
| U8 | The outdoor unit's fan has been stopped by a protective safeguard. | Major |
| U9 | The system has detected abnormal supply voltage, either too high or too low. | Urgent |
| UF | The compressor has been stopped by an overcurrent trip, typically because the compressor is locked and cannot turn. | Urgent |
| UH | The system has detected a voltage problem, such as overvoltage or voltage shortage, or a fault in the current sensor. | Urgent |
| UP | The compressor has been stopped by an overcurrent trip shortly after starting. | Urgent |
| Ud | The system has shut down on its overheating protection because of abnormally high pressure. | Major |
More Mitsubishi Electric guides:
- Fault Code L1
- Fault Code L2
- Fault Code L3
- Fault Code L4
- Fault Code L5
- Fault Code L6
- Fault Code L7
- Fault Code L8
- Fault Code L9
- Fault Code L10
- Fault Code L11
- Fault Code L12
- Fault Code L13
- Fault Code L14
- Fault Code L15
- Fault Code L16
- Fault Code L17
- Fault Code L18
- Fault Code L21
- Fault Code L22
- Fault Code L23
- Fault Code L24
- Fault Code L25
- Fault Code L26
- Fault Code L27
- Fault Code L28
- P8 Error Code
- Outdoor Unit Noisy, Outdoor Fan Bracket Issues
Want to check a code fast? Our air conditioner fault code lookup covers the full Mitsubishi Electric list below plus 14 other brands, with plain English meanings and safe checks.
Need Help?
T&K Airpower are specialist Mitsubishi Electric repairers and Authorised Service agents. With over 40 years of combined experience, we can help fix any Mitsubishi Electric air conditioning systems in Adelaide, South Australia. Please reach out to book a diagnostic today
Book A Service
We’ll call or text you back ASAP!
Adelaide's Mitsubishi Electric Air Conditioner Service and Repair Specialists
Your reliable experienced team of air conditioning mechanics, specialising in the service and diagnostic repairs of Mitsubishi Electric products.
30 years experience with Mitsubishi Electric products!
Adelaide’s only warranty agent for Mitsubishi Electric VRF City Multi units!
Mitsubishi Electric specialists for troubleshooting and repairs!