Home / Blog /

Written by Oliver Hastings on 13 November 2026
Bathroom Fan Light Not Working? What We Found in Hewett
A bathroom fan light not working is a common electrical call in Adelaide. In Hewett, the light section of a bathroom combination fixture stopped working while the fan and heat lamps continued to run. We attended, confirmed the LED driver had failed, and replaced it with a new driver the homeowner had already sourced. The fixture tested working before we left.
The Job In Brief
- Suburb: Hewett, South Australia
- Fixture: Bathroom combination unit (light, exhaust fan, heat lamps)
- Symptom: LED light section not working; fan and heat lamps unaffected
- What we confirmed: LED driver faulty; fixture working after replacement
- Root cause: Failed LED driver
- Fix: Rewired new LED driver (customer-supplied part)
- Electrical fault call-out: $99 inc GST
- Repair guide price: About $300 to $400 inc GST (correct at 12 November 2026)
- Outcome: Tested working
The Fault
The homeowner reported that the light section of their bathroom combination fixture had stopped working. The fan and heat lamps in the same unit were not reported as faulty. The homeowner had already purchased a replacement component and needed a licensed electrician to wire it in.
When our technician attended, they confirmed the LED driver in the original fitting had failed. The LED driver is the component that converts the 230V AC mains supply into the low-voltage direct current an LED module requires to operate. When the driver fails, the LED receives no usable power, and the light does not come on, while other components in the fitting that draw from different power paths continue to function normally.
What We Tested
On arrival, we confirmed the LED driver was faulty. The LED driver is the component responsible for powering the LED module. When the driver fails, the LED stops working while the fan motor and heat lamps, which draw power through separate components, continue normally. That pattern was consistent with what the homeowner had reported, and confirming the driver as the failing component was the necessary step before any replacement could proceed.
After fitting the new driver, we tested the fixture to confirm the light was working. A post-repair test is standard on every domestic electrical repair we complete in Adelaide.
All electrical work in South Australia must be certified under the Electricity Act 1996. The Office of the Technical Regulator oversees electrical trade licensing and the issuing of Electronic Certificates of Compliance (eCoC) in this state, which are mandatory for all electrical installation and repair work.
How We Fixed It
The homeowner had already purchased a replacement LED driver before our arrival. The technician quoted for the work on site, the quote was approved, and the new driver was rewired into the existing fitting.
The parts involved were:
- One LED driver (customer-supplied)
The work involved disconnecting the failed driver from the mains supply, connecting the replacement driver, and securing it inside the fixture. Even when a replacement part is already on site, this wiring work must be carried out by a licensed electrical contractor. Under the Plumbers, Gas Fitters and Electricians Act 1995 (SA), all electrical installation, alteration, and repair requires a licensed contractor and a Certificate of Compliance on completion. The ABLIS licence register outlines the South Australian licensing requirements in detail.
For fault finding or repair across all residential electrical work in Adelaide, see our domestic electrical repairs service.
| Stage | What we did | What it showed |
|---|---|---|
| Diagnosis | Confirmed the LED driver was faulty | Driver had failed; no usable power to the LED module |
| Repair | Rewired new LED driver (customer-supplied) into the fitting | New driver connected and secured |
| Post-repair test | Tested the fixture after replacement | Light now working |
Key Takeaways
- If only the light is out but the fan and heat lamps still work, the LED driver is the most likely fault. The driver is specific to the LED module; a failure there does not affect the other components in the fitting.
- Signs a driver may be approaching failure include flickering, lights that are noticeably dimmer than usual, or a light that takes longer to come on. A light that stops entirely is consistent with a fully failed driver.
- What you can safely check yourself: confirm the circuit breaker or safety switch has not tripped at the switchboard; check the wall switch is operating; listen for unusual noises from the fan section. If those checks show nothing obvious, stop and call a licensed electrician.
- Mains-voltage wiring inside a bathroom ceiling fitting is not a DIY job. Bathroom zones carry additional installation requirements under AS/NZS 3000, and all repair and replacement work must be certified by a licensed electrician.
- If you have already sourced a replacement driver, that is fine. As this job shows, the electrician can wire in a customer-supplied part. Confirm the replacement matches the original output specification and is rated for the application before purchase.
The Resolution
The technician replaced the LED driver with the customer-supplied part, tested the fixture, and confirmed it is now working. No further faults were identified during the visit and no additional work was recommended.
If you have an electrical fault in your Adelaide home, our domestic electrical repairs team handles lighting faults, power points, switchboards, and safety switches across the metropolitan area. The electrical fault call-out is $99 inc GST.
“In a bathroom combination unit, one function out while the others keep running usually points straight to the driver or the lamp. It is nearly always a repair, not a replacement, if someone gets to it promptly.” Oliver Hastings, T&K Airpower

Frequently Asked Questions
Why has the light on my bathroom fan stopped working but the fan still runs?
In a bathroom combination unit, the light, fan, and heat lamps each draw power through their own circuit paths inside the fitting. The LED light runs through its own driver component. If the driver fails, the light stops working while the fan and heat lamps continue normally. This is a common fault and is usually a straightforward repair for a licensed electrician.
What is an LED driver and why does it fail?
An LED driver converts the 230V AC mains supply into the low-voltage direct current an LED module needs to operate. It also regulates the supply to protect the LED from voltage fluctuations. Drivers can fail for various reasons. Heat is a well-documented factor: a driver operating in a confined ceiling space without adequate ventilation will degrade more quickly. Flickering, unusual dimness, and a light that stops turning on altogether are common signs the driver may be failing.
Can I replace an LED driver myself?
No. Any work that involves connecting to or disconnecting from mains wiring in South Australia must be carried out by a licensed electrical contractor. This applies even when you already have the replacement part on hand. A Certificate of Compliance must be issued by the electrician on completion of the work.
How much does it cost to replace an LED driver in Adelaide?
The electrical fault call-out is $99 inc GST. The repair itself carries a guide price of about $300 to $400 inc GST depending on access and time on site (correct at 12 November 2026). These are guide figures only and your technician will quote before starting work.
Can I supply my own replacement LED driver?
Yes, as this job shows. The homeowner had already purchased the correct driver before our visit and the technician wired it in. If you do source the part yourself, check that the voltage and current output match the original specification and that it is rated for bathroom or wet-area use if the fitting is in a bathroom zone.
Do I need to replace the whole unit if the LED light fails?
Not necessarily. If the fan and heat lamps are working and the fault is confirmed as a failed driver, replacing the driver alone is often sufficient. A full unit replacement may make sense if multiple components have failed or the driver is no longer available separately. Your electrician can advise once they have assessed the fixture.
What other electrical work does T&K Airpower handle?
Our domestic electrical repairs team covers lighting faults, power point failures, safety switch issues, and switchboard work across Adelaide. We also repair and service all major brands of air conditioning. If you are weighing up whether to repair or replace a system, our repair or replace calculator and air conditioner servicing page are good places to start.
Need Help?
Call us on 08 8296 7888 or book online at tkairpower.com.au. T&K Airpower has been trading in Adelaide since 1996, holds the relevant electrical and refrigeration licences for South Australia, and is an authorised warranty agent for Mitsubishi Electric, Temperzone and Hitachi. We repair before we replace.